58
Connections
The Connections Configuration Tab allows the creation, deletion, and management of input-
output connections. The Statistics tab includes all connected input/output status, which allows
the operator to immediately pinpoint errors.
Connections Configuration Tab
The Connections configuration tab is depicted below. The message “No Connections” will be
displayed if there are no configured input/output connections in the BBG-1090-TRX-MPEG. As
indicated in the figure, the Connections configuration area is divided into two parts: a source
selection, and a destination selection.
Source
Selection
Destination
Selection
To establish a connection, simply select a source and a destination, and click on Apply. Each
connection end-point is determined by three parameters:
•
The port type: ASI, Ethernet, Transcoder.
•
The actual port (stream): the ASI port number, the actual Ethernet stream.
•
The program: since in general a stream can have multiple programs, an individual
program number will need to be specified.