Disabled: no redundancy.
•
Automatic: a redundant address/port can be defined, and the input will automatically
switch between primary and backup if the stream disappears. If this option is selected, a
new field is displayed, where the Switch Time can be configured; valid values are
between 2 and 45 seconds:
•
Manual: a redundant address/port can be defined, but the input will not automatically
switch – that will have to be done manually by the operator.
Manual redundancy flips are done by selecting an existing IP Input port for configuration. This
operation is described in the Active IP Inputs Table section.
Addressing Parameters
The Addressing parameters allow the definition of one or two address/port combinations for
reception. If Backup is set to Disabled, only the primary settings are displayed; otherwise, both
the primary and backup settings are displayed, as shown below.
The Primary/Backup addressing parameters are configured as follows:
•
UDP Port: selects the UDP port to receive from. Valid values are between 1 and 65535.
Note that, in traditional IP networks, UDP ports between 1 and 1023 are reserved for