55
The following applies to all the PID fields:
PIDs can be entered in decimal or hexadecimal. For decimal values,
simply enter the desired value. For hexadecimal values, precede them by
“0x” as depicted above.
PID values must be between 0x20 and 0x1FFE (32 and 8190 in decimal).
PID values must be distinct, with the exception of Video PID and PCR
PID. These can be the same or distinct.
If the Video Compression parameter is set to MPEG-2, the following parameters are not
available:
•
MBAFF
•
Profile
•
Successive B-Frames
•
Reference Frames
•
GOP Type
Transcoder Established Connections
If there are any connections already established to the transcoder session, they will be shown in
the Established Connections area. Individual connections can be removed by checking the box
in front of them.
Transcoder Add Connections
Connections to the transcoder can be added directly after configuration. The transcoder has both
an input (to receive a stream to be transcoded) and an output (to provide the transcoded stream);
therefore, two fields are provided:
Содержание BBG-1090-TRX-MPEG