57
The possible indicator status values are:
•
OK: The transcoder session is operating normally (it has a valid input and is
transcoding that input).
•
Waiting for Input: The transcoder session is configured and enabled, but it has no
input. This can be because it has no connection to an input port, or because the port has
no programs, or because the selected program is not available in the connected port.
Dashboard Card State will be yellow unless there is a higher-priority alarm active.
•
No Output: The transcoder is not generating an output stream. This can happen if the
input stream is corrupted, encrypted, or has an unsupported compression type. This
status may also be briefly displayed when the transcoder is starting. Check the input to
see if it is decodable. Contact Support if you get this status with a clean decodable
stream. Dashboard Card State and the Status LED will be red.
•
Status Unknown: The control system is unable to manage the transcoder session.
Contact Support if you get this status. Dashboard Card State and the Status LED will be
red.
•
Config Failed: The configuration parameters are invalid. Contact Support if you get
this status. Dashboard Card State and the Status LED will be red.
•
Idle: The transcoder session is disabled (by setting Transcoder State to Stopped in
the Transcoder Configuration Parameters).