BBG1070QS-OM (V1.8)
BBG-1070-QS PRODUCT MANUAL
3-55
Setup/Operating Instructions
BBG-1070-QS Function Menu List and Descriptions
(continued)
• Preset Enter/Save/Delete
Locks and unlocks editing of presets to prevent accidental overwrite as
follows:
• Protect (ready): This state awaits Protected and allows preset Save/
Delete button to save or delete current settings to the selected preset.
Use this setting when writing or editing a preset.
• Protected: Toggle to this setting to lock down all presets from being
inadvertently re-saved or deleted. Use this setting when all presets
are as intended.
• Create New Preset: Field for entering user-defined name for the preset
being saved (in this example, “IRD Rcv122”).
• Save: Saves the current settings under the preset name defined above.
• Preset Save/Load Controls
Note: If using Cascade Config mode where a global preset is to apply in some manner to all units in the chain, it is
recommended to have all units in the chain set up as desired, and then save the preset on the last unit in the chain.
This helps ensure that all saved states in each unit will be saved in an “umbrella” preset encompassing all units in the
chain.
Table 3-1
BBG-1070-QS Function Menu List — continued
Protected state –
changes locked out
Ready (open) state –
changes can be applied
• Select Preset: drop-down allows a preset saved above to be
selected to be loaded or deleted (in this example, custom preset
“IRD Rcv122”).
• Load Selected Preset button allows loading (recalling) the
selected preset. When this button is pressed, the changes called
out in the preset are immediately applied.
• Update Selected Preset button allows saving any settings
changes to the selected preset. When this button is pressed, the
changes in effect are rolled into the selected preset.
• Delete Selected Preset button deletes the currently selected
preset.
• Load Factory Defaults button allows loading (recalling) the
factory default preset. When this button is pressed, the changes
called out in the preset are immediately applied.
Note: Load Factory Defaults functions with no masking. The
Preset Layer Select controls have no effect on this control
and will reset all layers to factory default.
• Download Presets saving the preset files to a folder on the
connected computer.
•
•
•