BBG1070QS-OM (V1.8)
BBG-1070-QS PRODUCT MANUAL
3-15
Setup/Operating Instructions
BBG-1070-QS Function Menu List and Descriptions
(continued)
• Decrease/Increase Spacing Controls
Provides tailoring of the PiP image sizes relative to background fill.
• Layout Flip Controls
For local inputs to the unit, allows PiP layout to flip top/bottom or L/R.
Note: • The following controls are used for individual PiP (per-PiP) layout and positioning control.
• Any sizing/positioning performed using cloning controls can be overwritten using these controls.
• PiP Size/Position Edit/Select
Individually selects any of the five PiP inputs to be selected for sizing/
positioning edits, and enables PiP insertion into the merged output.
(In this example, PiP 1 is selected for editing.)
Note: • These controls are intended only for local inputs and not a
cascade underlay imported from an upstream BBG-1070-QS unit.
• For multi-unit setup using Cascade Config mode/setup, Clone
Settings from any of the units in the chain can be cloned to any
unit in the chain (i.e., all units in the chain appear in the Clone
Settings From and Clone Settings To drop-downs). See
Cascade Config Setup Controls (p. 3-41) for more information.
Table 3-1
BBG-1070-QS Function Menu List — continued
Pressing Decrease
progressively expands all PiPs
uniformly over the fill areas,
allowing each PiP to
symmetrically occupy more of
the image area
Pressing Increase
progressively reduces all PiPs,
allowing fill to symmetrically
occupy more of the PiP image
area
Содержание BBG-1070-QS