BBG1070QS-OM (V1.8)
BBG-1070-QS PRODUCT MANUAL
3-43
Setup/Operating Instructions
BBG-1070-QS Function Menu List and Descriptions
(continued)
Table 3-1
BBG-1070-QS Function Menu List — continued
Cascade Configurator Example and Setup Tips
The following shows an example where a 17:1 multiviewer is furnished using Cascade Config with four BBG-1070-QS units
forming a 4-unit chain (5+4+4+4 PiP inputs which provides a 17-PiP multiviewer).
A very important and clarifying aspect of using Cascade Config is when the units are cascade network defined (as described on
the previous page) the DashBoard UI simply combines all the discrete units as a single device. A primary function of Cascade
Config is to provide a global, centralized setup point for all units in the chain, thereby creating (from the UI perspective) a virtual
single-device multiviewer.
As shown to the left, all DashBoard layout and attribute controls appear and function
just like using the single-unit BBG-1070-QS. The only difference is now all the PiPs
can be accessed from a single point (rather than going from unit-to-unit). In our
example, the PIP Layout drop-down now has Configure definers for PiPs 1 thru 17
instead of just PiPs 1 thru 5 for a single, non-networked unit.
With Cascade Config, the only setup aspects that remain local to each unit in the chain
are:
• Input Routing (each unit still needs its per-unit input sources defined)
• Output Audio (each unit needs to know whether to pass audio from an upstream
unit, or use audio sourced from a local PiP input
• Output Format (Output format will likely be set consistent across all units in the
chain. If a format change is needed for the final output, this is best accomplished by
doing this on the last unit in the chain.)
PIP 1 (A1)
PIP 2 (A2)
PIP 3 (A3)
PIP 5 (A5)
PIP 4 (A4)
PIP 6 (B1)
PIP 9 (B4)
PIP 8 (B3)
PIP 7 (B2)
PIP 10 (C1)
PIP 13 (C4)
PIP 12 (C3)
PIP 11 (C2)
PIP 14 (D1)
PIP 17 (D4)
PIP 16 (D3)
PIP 15 (D2)
Shown below is the example multiviewer setup described in this example. For this example, Idents are set as PIP1 thru
PIP 17 for the 17 PiPs in the merged MV output. Also for example purposes, the parenthetical designations correlate to the
unit A thru D per-unit PiP inputs that provide the 5+4+4+4 that result in the 17-PiP aggregate.
— Example continued on next page —