CNCWL-XN Series Machines
Chiller Set-up
Water Chiller
:
The water chillers shown below are the CW-3000 (Figure 3b) and the CW-5000 (Figure 3c). These water
chillers will come as shown with 3/8” flexible hose lines and power cord. The water chiller will have reservoir
with the capacity to hold a little under 3 gallons of distilled water.
You will need both flexible hoses to run the water from the chiller to the machine.
On the machine and the chiller there will be nozzles labeled “out” and “in”. One of these flexible hoses will go
from the “out” from the chiller and “in” to the machine. The next hose will go “out” from the machine and “in”
to the chiller. Then plug in your chiller to an electrical outlet.
Chiller Signal Cable:
The chiller will come with a chiller signal cable, this cable needs to be plugged into the “Chiller Signal” outlet
located at the back of the machine. If this cable is not plugged in, the laser will not fire.
How to Ground Your Machine: Located on the back of the machine, there will be a ground connector. This is an
external ground designed to help eliminate static electricity. Start by running the ground wire from the
connection on the machine to any grounded outlet or directly to earth.
✎Note: The water temperature should always be between 59-77 degrees Fahrenheit when running the
machine. (15-25 Degrees Celsius)
The Air Pump
The air pump is used to blow air through the laser head.
This will blow away debris and smoke from the laser beam while allowing for a cleaner cut and protecting the
lens.
✎Note: The air compressor on/off switch should be close by and preferably on the same circuit as the water
chiller and exhaust fan to ensure it is in operation while running the laser machine. Air Pump: The air pump
will come with 6mm nylon black tubing. This tubing will attach to the fitting located at the tip of the pump
and to the backof the machine with the nozzle labeled “air in”. Lastly, plug the air pump into the electrical
outlet.
The air pump will come with 6mm nylon black tubing.
This tubing will attach to the fitting located at the tip
of the pump and to the backof the machine with the
nozzle labeled “air in”. Lastly, plug the air pump into
the electrical outlet
CNC Warehouse LLC 10
Содержание CNCWL- 5136-XN
Страница 2: ...CNCWL XN Series Machines CNC Warehouse LLC...
Страница 6: ...CNCWL XN Series Machines CNC Warehouse LLC 2...
Страница 8: ...CNCWL XN Series Machines CNC Warehouse LLC 4...
Страница 10: ...CNCWL XN Series Machines CNC Warehouse LLC 6...
Страница 27: ...CNCWL XN Series Machines Rotary Option Continued Select the User Tab CNC Warehouse LLC 23...
Страница 30: ...CNCWL XN Series Machines number in Millimeters 5 Change the rotating speed to 50 CNC Warehouse LLC 26...