In the control, press the "play" icon, the spindle is now turned on and the symbol now
appears in red.
Figure 3.5.7
Now you should measure at the screw terminal, + 5 volts.
For problems, proceed as described in "Test the outputs (A1, A2)".
3.6
Inverter and HF milling spindle
Testing FOR/DCM:
In the Estlcam Software:
Open Estlcam and got to „View->CNC Controller (F2)“
In the window, press the "play" icon, the spindle is now turned on and the symbol now
appears in red. (See figure 3.5.6)
Check the passage from FOR to DCM, the red measuring line of your measuring
device to FOR and the black to DCM.
Figure 3.5.8