READ AND FOLLOW ALL INSTRUCTIONS
• Read this manual completely before attempting installation. Failure to install in accordance with the installation
instructions could void warranty and result in injury or death.
• All permanent electrical connections should be made by a qualified electrician.
• A pressure wire connector, labeled “bonding lugs”, is provided on the outside of the unit to permit connection to
a minimum No. 6 AWG (13.3 mm2) solid bonding conductor between this point and any metal equipment, metal
enclosures of electrical equipment, metal water pipes, or conduit within 5 feet (1.5 meters) of the unit as needed to
comply with local requirements.
• Install at least 5 feet (1.5 meters) from wall of pool.
• Follow all applicable electrical codes.
•
DANGER
ELECTRIC SHOCK HAZARD:
Be sure to turn power OFF and disconnect from power source before
any service work is performed. Failure to do so could result in serious injury or death.
• The UV-C Pro must be installed in an outdoor location, or indoors in a forced air ventilated room, and installed so
that the orientation is exactly as shown in Figure 3. Install to provide water drainage of generator to protect electrical
components.
• Mount the UV-C Pro so that it is inaccessible to anyone in the pool. Never attempt any servicing while unit is wet.
• For your safety, do not store or use gasoline, chemicals or other flammable liquids or vapors near this or any other
appliance.
• To maintain cosmetic integrity, protect this unit from direct prolonged sunlight exposure.
• To reduce the risk of injury, do not permit children to use this product, unless they are closely supervised at all times.
• ENVIRONMENTAL NOTICE:
Hg-Lamp CONTAINS MERCURY. Manage in accordance with disposal laws.
See: www.lamprecycle.org
• If unit is not operated according to instructions, high dosages of harmful substances may potentially be released.
• Product has met the requirement of NSF/ANSI 50, Annex H.1 for supplemental disinfection and is designed for pools
that are in compliance with the U.S. Model Aquatic Health Code (MAHC). Installed flow rates must not exceed max
listed flow rates to maintain NSF product listing as well as ensuring proper microbial performance.
• NSF/ANSI 50, Section 13 disinfection efficacy testing for 3 log (99.9%) or greater of Pseudomonas Aeruginosa and
Enterococcus Faecium. Specific residual levels of EPA registered disinfection chemicals may be required by the
regulatory agency having authority. Product is designed for supplemental disinfection and should be used with
registered or approved disinfection chemicals to impart residual concentrations.
SAVE THESE INSTRUCTIONS!
IMPORTANT INFORMATION