2
Figure 1: UV-C Generator Overview
2A. Pool Preparation
To achieve optimal performance from the system, the pool must be as clean as possible to start with.
1. Backwash or clean filters one day before starting the generator.
2. Superchlorinate pool water using a chlorine based shock treatment so the water has a sustained 1-3 ppm free
chlorine level.
3. Test pool chemistry and adjust pH between 7.4 and 7.6. Adjust total alkalinity between 80 and 120 ppm.
4. Run pool filtration continuously for 24 hours prior to starting UV-C Pro system.
2B. Location
• Ambient Temp.: 40°F - 110°F (5°C - 43°C)
• Locate the unit indoors or outdoors in a clean area protected from rain and direct sunlight.
• Locate the unit out of reach of sprinklers or drainage spouts. Allow sufficient access for maintenance (2 ft clearance
above and 1 ft around the unit) and all plumbing and electrical hookups. Allow additional clearance in front of the
unit to allow for door swing and lamp service.
2C. Mounting
• UV-C PRO-200 models are shipped with hardware for either floor or wall mounting. Attach the mounting rails in the
desired position (bottom or back of the enclosure) and secure with the screws provided.
• UV-C PRO-350 and 500 models are floor mount only and have mounting holes integrated into the base supports.
• Mount the UV-C Pro securely using appropriate hardware or anchors for the surface and as needed to meet local
building code requirements.
1A. Description
DEL UV-C Pro products use UV-C light to provide superior disinfection of pool and spa water. The system utilizes low pressure
(254 nm) lamps in a modular design to provide a completely integrated system. Controls and UV-C reactors are all in one
cabinet.
With the use of UV-C microorganisms are destroyed, chlorine dependence is significantly reduced, and water clarity is
optimized to produce crystal clear results.
UV-C is compatible with all traditional sanitizers. These systems are cost effective to operate and maintain. UV-C Pro is NSF
certified for supplemental disinfection of pools and spas.
UV-C PRO-200D
UV-C PRO-350D
UV-C PRO-500D
FLOW
65-200 GPM
125-350 GPM
125-500 GPM
INLET/OUTLET
3 in
4 in
6 in
UV LAMP QTY
8
16
20
PLC CONTROL
Yes
VOLTAGE (1Ø)
240 VAC
CURRENT
2.0 A
3.4 A
4.2 A
Table 1: UV-C Pro Sizing Chart
1B.Specifications
See
Table 1
for list of models and specs that apply to this manual. Images shown are model UV-C PRO-500D but manual
instructions apply to all models, unless otherwise noted.
Water Inlet
Water Outlet
Bonding Lugs
2. INSTALLATION