5A. Troubleshooting

Knowledge of electrical applications is required for troubleshooting. Contact a certified electrician if you are unsure of your 

ability to service the equipment. Improper servicing will void generator warranty. If any condition persists contact CMP 

Technical Support (see 

Section 5B

).

The HMI screen will provide immediate text notification of all system alerts.  Other alert messages may occur that are not 

listed below. The HMI also includes alarm history and fault counters that may be accessed for further help as described above.

Symptom:

 HMI screen appears unpowered.

1.  No power to the UV-C Pro:

a.  Check circuit breaker at the power distribution box.

b.  Check for loose connections or wiring breaks in the main power wiring leading to the UV-C Pro.

c.  Check internal circuit breaker.

 

Symptom:

 “SYSTEM WAITING ON REMOTE START (CONTACTS)” message.

1.  Remote start contacts are open. Verify that remote start contacts are wired and operating properly. 

Symptom: 

“WAITING ON SYSTEM FLOW” message.

1.  Insufficient flow through UV-C Pro.

a.  Verify that the main system pump is running properly and that filter and skimmers are clean.

b.  Verify that pool valves have not been adjusted to limit flow below the minimum requirement.

2.  Clear any blockages in return line.

3.  Verify proper operation of flow switch. Replace as necessary.

 

Symptom:

 

“LOW SYSTEM PRODUCTION, CHECK SYSTEM” message.

1.  Check lamp connector plugs for complete connection.

2.  Check UV lamps. Replace as necessary.

3.  Check ballasts. Replace as necessary.

 

5. TROUBLESHOOTING & RESOURCES

Содержание DEL AOP PRO 200

Страница 1: ...4 2813 01 Rev A CMPCOMMERCIAL COM DEL UV C PRO 200 350 500 INSTALLATION INSTRUCTIONS PRODUCT MANUAL...

Страница 2: ...ssible to anyone in the pool Never attempt any servicing while unit is wet For your safety do not store or use gasoline chemicals or other flammable liquids or vapors near this or any other appliance...

Страница 3: ...on 4 3C System Shut Down 6 3D Water Chemistry 6 4 Maintenance Service 4A System Electromechanical Overview 7 4B UV Reactor Service and Maintenance 7 4C PLC Memory Battery Backup Replacement 10 4D Wint...

Страница 4: ...esults UV C is compatible with all traditional sanitizers These systems are cost effective to operate and maintain UV C Pro is NSF certified for supplemental disinfection of pools and spas UV C PRO 20...

Страница 5: ...a protected from rain and direct sunlight Locate the unit out of reach of sprinklers or drainage spouts Allow sufficient access for maintenance 2 ft clearance above and 1 ft around the unit and all pl...

Страница 6: ...to an external device that closes when the pool pump is ON and opens when it is OFF Failure to use the remote start contacts may result in damage to the unit not covered under warranty 2E Plumbing The...

Страница 7: ...screen includes status indicators and text to communicate real time system conditions as well as access to historical data The five function buttons allow user navigation of the menus and user input T...

Страница 8: ...lert reminders More than 10 remaining no banner message 10 remaining SERVICE SOON banner message 5 remaining SERVICE REQUIRED banner message 0 remaining SERVICE PAST DUE alert banner message with yell...

Страница 9: ...Followed for servicing or storage 1 Shut off water flow to the unit and or close isolation valves if available 2 Shut off power at the breaker 3 Open enclosure door to access internal components NOTE...

Страница 10: ...p is difficult to remove use a slight twisting motion or remove the lamp retainer AVOID TOUCHING THE UV LAMP GLASS WITH YOUR BARE HANDS Oils on your hands can cause hot spots on the UV lamp and shorte...

Страница 11: ...8 4 MAINTENANCE SERVICE Inlet Flange Outlet Flange Flow Switch Location not shown Ballast UV Reactor Figure 3 UV C Pro Electro Mechanical Overview...

Страница 12: ...emoval Figure 5 UV Quartz Tube lnstallation NOTE DAMAGES CAUSED BY BROKEN QUARTZ TUBES ARE NOT COVERED UNDER THE LIMITED WARRANTY UV Lamp Quartz Tube Lamp Retainer Sealing O ring Lamp Retainer Screws...

Страница 13: ...tom of the quartz tube 3 Connect the UV lamp connector to the connector on the ballast ENVIRONMENTAL NOTICE Hg Lamp CONTAINS MERCURY Manage in accordance with disposal laws See www lamprecycle org Fig...

Страница 14: ...box b Check for loose connections or wiring breaks in the main power wiring leading to the UV C Pro c Check internal circuit breaker Symptom SYSTEM WAITING ON REMOTE START CONTACTS message 1 Remote s...

Страница 15: ...u call 1 800 733 9060 or visit www cmpcommercial com 5D Standard Replacement Parts List DESCRIPTION PART NUMBER REPLACEMENT INTERVAL PLC MEMORY BACKUP BATTERY included with PLC option only 5 1402 Annu...

Страница 16: ...Pro Pressure Drop Characterization NOTE Tested on simulated recirculation system using a variable speed pump No back pressure added Actual results will vary depending on pump and plumbing variables AP...

Страница 17: ...utlet unions or flanges b Flow the cleaning solution from bottom to top 2 When cleaning is complete drain the UV C Pro completely from the inlet union or flange and run the pool system immediately for...

Страница 18: ...Below Keep for Your Records Installer _______________________________________________________________ System Purchased From ______________________________________________ Installation Date __________...

Страница 19: ...16 NOTES...

Страница 20: ...CMP LLC 36 HERRING ROAD NEWNAN GA 30265 WWW CMPCOMMERCIAL COM 1021ab...

Отзывы: