AN202
V1.0 | Page 15/73
www.cmostek.com
the transmission, resetting the TWI bus and RF part to allow RF part to enter the low power status of sleep.
The disadvantage is that users have to do a cumbersome configuration process every time.
Note:
Users may ask if they can only execute configuration parameters once after power-up. This method is to hold
the RFDAT to low and continue until the end of the t
STOP
time, as shown in the following figure:
The 1st Transmission Cycle
(1 ) - TWI_RST
(2 ) - SOFT_RST
Hold RFDAT = 0
Wait for t
STOP
TRANSMISSION
Reset TWI
One Transmission Cycle
TRANSMISSION
(1 ) - TWI_RST
(3 ) - TWI_OFF
(2 ) - Step2 to Step6
Hold RFDAT = 0
Wait for t
STOP
Figure 2-11. Only Execute Configuration Parameters Once
But this method is unable to achieve the low power consumption, because users trigger the RF internal
register to save temporarily the configuration content, these temporary storage functions need to consume a
certain amount of power (100uA or so); unless users do not execute the configuration mechanism, or do not
use temporarily saving register (i.e. there is nothe process from Step2 to Step6, shown as below). Users only
rely on the RF internal burning parameters as theconfiguration parameters.
One Transmission Cycle
(1) - TWI_RST
(2) - SOFT_RST
(1) - TWI_RST
(2) - TWI_OFF
(1) - TWI_RST
(2) - SOFT_RST
TRANSMISSION
Reset TWI
One Transmission Cycle
(1) - TWI_RST
(2) - TWI_OFF
(1) - TWI_RST
(2) - SOFT_RST
TRANSMISSION
Figure 2-12. Burning Way Transmission Process (Not configuring the register)