E – Symbols on pump, consumables & accessories 

 

System Symbols 

The  following  symbols  are  used  on  the  Caesarea  Medical  Electronics  Ltd.  T34  Syringe  Pump 
and  components.  Labels  on  the  pump  or  statements  in  this  manual  preceded  by  any  of  the 
following  words  and/or  symbols  are  of  special  significance  and/or  are  intended  to  help  you  to 
operate the pump in a safe and successful manner.   

 

 
Attention, consult accompanying Instructions. 

 

 

 

CSA mark 

0473

                      

CE mark indicates conformance to Medical Device Directive 93/42/EEC. 

 

 

 

Do not dispose of in municipal waste. Symbol indicates separate collection 
for  electronic  equipment.  (WEEE  Directive  2002/96/EEC). 

NOTE

:  Does 

not apply to the battery. 
 
Do  not  dispose  of  battery  in  municipal  waste.  Symbol  indicates  separate 
collection for battery is required. 

 

 
The use of single-use disposable components on more than one patient is a 
biological hazard. Do not reuse single-use disposable components.    

 

 
Type CF applied part.  

 

Date of Manufacture 

 

Serial Number 

 

Expiry Date (consumables) 

 

Lot Number (consumables) 

 

Sterilized with Ethylene Oxide 

 

 

F - Installation and Inspection 

Unpacking 

1.  

Remove the T34 Syringe Pump & accessories from the box and inspect for damage 
during shipment or storage. 
Do  not  use  T34  if  there  are  any  obvious  signs  of  damage.  Return  for  inspection  by 
authorized service personnel. 

2. 

 Make sure you have the following items: 

 

T34 Syringe Pump 

 

Patient Guide 

 

Alkaline 9V batteries 

 

Carry Pouch 

 

Lockbox  

 
If  any  items  are  missing  or  damaged,  contact  your  supplies  department  to  order 
replacement. 

LOT

 

 
 STERILE   EO

Содержание NIKI T34

Страница 1: ...NIKI T34 SYRINGE PUMP Instruction Manual Ref 100 090SS Edition June 2008 0473...

Страница 2: ...Batteries 10 I Access Codes Keypad Lock 11 J Infusion set up programming 12 K Using Accessories with T34 Syringe Pump 16 L Recommended Checks during infusion 17 M Advanced Functions of the T34 18 N Ch...

Страница 3: ...adults or for pediatric use The T34 syringe pump can be easily concealed beneath clothing in a shoulder holster and combination belt A compact lockbox is provided to protect the Pump from damage and o...

Страница 4: ...that unintended programming and key presses do not occur The T34 syringe is contained within a locked box Only the healthcare provider is able to open the box After the healthcare provider programs th...

Страница 5: ...nt may cause serious injury or death Before connecting to the patient purge all air from the syringe and the administration set Depending on the route of administration and the volume of air air embol...

Страница 6: ...e subject it to extreme physical stress This could damage the pump which may impair the operation of the pump and or the accuracy of the infusion If the pump is dropped return the pump for inspection...

Страница 7: ...3 ON OFF key Switches the pump on and off 4 NO STOP key a Takes user back a step b stops pump 5 YES START key Confirms choices 6 Down arrow key scrolls between options 7 Up arrow key Scrolls between...

Страница 8: ...ttery Do not dispose of battery in municipal waste Symbol indicates separate collection for battery is required The use of single use disposable components on more than one patient is a biological haz...

Страница 9: ...Precautions Administration Sets Administration sets must be compatible with the medicine delivered Please check with the manufacturer of the infusion set before use Visually inspect packaging and cont...

Страница 10: ...y and need to be replaced more often Do not use non alkaline or rechargeable batteries There is some variation in size between different brands of batteries Never try to force a battery into the batte...

Страница 11: ...nu used for service and or repair of the Pump is also protected by a special access procedure and different code from Change Set Up Keypad Lock The T34 allows all users to lock the operation of the ke...

Страница 12: ...tus 3 Load the syringe into the Pump prior to connecting the syringe to the patient 4 The LCD display will show PRE LOADING and the actuator will start to move Wait until it stops moving and the syrin...

Страница 13: ...he programmed infusion rate the user can purge the system once only up to a volume limit configured under Change Set Up max 0 5 ml To use this option after syringe confirmation a Press FF key b Ensure...

Страница 14: ...l show the default 16 Use the UP DOWN arrow keys to set the desired duration or press YES to confirm acceptance of the default duration Setting the Infusion Rate 17 The Pump calculates and displays th...

Страница 15: ...START to commence infusion 23 While running the LCD displays infusion Time Remaining top line Infusion Rate main central line and the bottom line will alternate between Syringe Size Brand and Pump De...

Страница 16: ...the T34 place it into the lockbox and carry pouch to protect the syringe Pump syringe contents from damage or tampering 1 Open the lockbox using the standard key that operates all T34 lockboxes 2 Plac...

Страница 17: ...ing the INFO key either a third press or waiting a few seconds returns the display to the main infusion display screen Excessive key presses or usage of the INFO feature will reduce battery life Use o...

Страница 18: ...programming to set a max min rate To titrate the rate up or down during infusion follow these steps Use the UP or DOWN arrows on the keypad to adjust the rate to the desired new setting as displayed...

Страница 19: ...es all events in log are correctly date and time stamped ensure local update for DST FF Key Operation Limits the forward movement of actuator caused by pressing the FF key during syringe loading 0 1 1...

Страница 20: ...Turn pump off Syringe Displaced Check Syringe Press YES to confirm One or more of the syringe detection sensors is not detecting up the syringe Check the syringe and re seat as necessary Pump Paused T...

Страница 21: ...new battery Service required The infusion is going too quickly has ended early or too slowly volume remaining in syringe at end of infusion Incorrect rate set Wrong syringe brand onfirmed during set...

Страница 22: ...ry Pump Paused Too Long Syringe Displaced Syringe Empty T34 Dimensions 169 x 53 x 23mm Classification Type CF Equipment degree of protection against electrical shock Housing ABS fire retardant Weight...

Страница 23: ...he patient and or the patient s assistants or family members in case of questions or concerns Training the Patient and or the Patient s Assistants or Family Members 1 Using the Patient Guide instruct...

Страница 24: ...ith a small dry brush to remove debris or other particles Between Patients Change the battery Before connecting the pump to a patient and periodically during use clean the unit using a lint free cloth...

Страница 25: ...returned to CME or its designated representative should be properly packaged using CME shipping cartons and inserts Inadequate packaging may result in damage to the pump This Limited Warranty shall no...

Страница 26: ...trained certified service centers or biomedical engineers Please consult your local certified engineers or return to your T34 distributor should this need arise For alternate site homecare application...

Отзывы: