91
10.7 Config - PC adaptation
An Ethernet interface is used to connect the welding power source to the
QDM (Qineo Data Manager) software. For the communication of the weld-
ing power source within the network, the IP address and the subnet mask
must be set.
Use the arrow keys to move to the desired position for entering numbers.
The selected number field is highlighted in white. You can select a number
between 000 and 255 by means of rotary knob 3. Use one of the arrow keys
to move to the next input field. Press the rotary knob to exit the input
mode.
10.8 Config - Clock
For an exact data recording during weld data monitoring the exact time
and the correct data are important. You can enter this data in the "Config
- Clock" menu. Use the arrow symbols to switch between the individual
menu items. The input is made with rotary knob 3.
The input is finished by pressing rotary knob 3. To exit the menu, press the
"Esc" key.
Puls 4 -Takt
V
0
A
1.2 mm Fe
82% Argon 18% Co
2
0.0
Konfig – PC Anpassung
IP - Adresse
185 .
168
. 169 . 200
Subnetzmaske
255 . 255 . 255 . 000
IP – Adresse SD- Modul
185 .
170
. 169 . 003
Subnetzmaske SD-Modul
255 . 255 . 255 . 000
Puls 4 -Takt
V
0
A
1.2 mm Fe
82% Argon 18% Co
2
0.0
Konfig – PC Anpassung
IP - Adresse
185 .
168
. 169 . 200
Subnetzmaske
255 . 255 . 255 . 000
IP – Adresse SD- Modul
185 .
170
. 169 . 003
Subnetzmaske SD-Modul
255 . 255 . 255 . 000
Figure 49. Config - PC adaptation
Содержание QINEO
Страница 4: ......
Страница 10: ......
Страница 11: ...11 Operational safety Block 1 Operational Safety...
Страница 29: ...29 Block 2 Basic information Qineo Champ Pro...
Страница 42: ...CHAMP Pro 42...
Страница 109: ...109 Block 4 Additional information...
Страница 124: ...124 SD module...
Страница 138: ...138 Commissioning 6 7 8 5...
Страница 140: ...140 Commissioning 7 5 6 The wire inlet must not touch the wire drive roller INFO...
Страница 145: ...145 Block 6a Error messages...
Страница 159: ...159 Block 6b General maintenance instructions...
Страница 160: ...160 1 Maintenance and Care 1 7 6 4 5 2 3 8 11 9 10 Optional external cooling unit 10 Optional crane suspension 3...
Страница 164: ...164...
Страница 165: ...165 Block 7 Automation...
Страница 184: ...184...
Страница 185: ...185...
Страница 186: ...www qineo de...