MAIN (2) - Config (Configuration)
10.4 Config - Water monitoring
The water monitoring is inactive if no sensors are available or the pump is
switched off, see chapter 10.1.3 on page 73.
Use the arrow symbols to switch between the individual menu items.
Water flow rate
In the menu "Water monitoring" the minimum water flow rate can be
monitored.
• The limit value is set in l/min. The limit value should not fall below
1.2 l/min.
• The start delay allows a trouble-free recording of the measured values.
In addition, an error must exist for a certain error time in order to be
detected as error.
• If "Message" has been selected, an output signal exists on the CAN bus
of the welding power source. This signal can be processed by a periph-
eral control (PLC). If "Abort" is selected, the Arc start command will be
reset in the event of an error.
Water temperature
In the "Water temperature" menu, the temperature of the coolant can be
monitored.
• The limit value is set in °C. The limit value should not exceed 60°C.
• The start delay allows a trouble-free recording of the measured values.
In addition, an error must exist for a certain error time in order to be
detected as error.
• If "Message" has been selected, an output signal exists on the CAN bus
of the welding power source. This signal can be processed by a periph-
eral control (PLC). If "Abort" is selected, the Arc start command will be
reset in the event of an error.
ATTENTION!
Puls 4 -Takt
V
0
A
1.2 mm Fe
82% Argon 18% Co
2
0.0
Konfig -Wasserüberwachung
Wasserüberwachung
Schwellwert (l/min) 1.0
Verzögerung (sek.) 1.0
Fehlerzeit (sek.) 1.0
Überwachung
Abbruch
Wassertemperatur
Schwellwert (ºC) 1.0
Verzögerung (sek.) 1.0
Fehlerzeit (sek.) 1.0
Überwachung
Melden
Puls 4 -Takt
V
0
A
1.2 mm Fe
82% Argon 18% Co
2
0.0
Puls 4 -Takt
V
0
A
1.2 mm Fe
82% Argon 18% Co
2
0.0
Konfig -Wasserüberwachung
Wasserüberwachung
Schwellwert (l/min) 1.0
Verzögerung (sek.) 1.0
Fehlerzeit (sek.) 1.0
Überwachung
Abbruch
Wassertemperatur
Schwellwert (ºC) 1.0
Verzögerung (sek.) 1.0
Fehlerzeit (sek.) 1.0
Überwachung
Melden
Figure 38. Config" - "Water monitoring" menu
Содержание QINEO
Страница 4: ......
Страница 10: ......
Страница 11: ...11 Operational safety Block 1 Operational Safety...
Страница 29: ...29 Block 2 Basic information Qineo Champ Pro...
Страница 42: ...CHAMP Pro 42...
Страница 109: ...109 Block 4 Additional information...
Страница 124: ...124 SD module...
Страница 138: ...138 Commissioning 6 7 8 5...
Страница 140: ...140 Commissioning 7 5 6 The wire inlet must not touch the wire drive roller INFO...
Страница 145: ...145 Block 6a Error messages...
Страница 159: ...159 Block 6b General maintenance instructions...
Страница 160: ...160 1 Maintenance and Care 1 7 6 4 5 2 3 8 11 9 10 Optional external cooling unit 10 Optional crane suspension 3...
Страница 164: ...164...
Страница 165: ...165 Block 7 Automation...
Страница 184: ...184...
Страница 185: ...185...
Страница 186: ...www qineo de...