Code
State
Default Min
max
setting
interval
unit
2.10
T4C1
The ambient temperature 1 of climate related curves for
cooling mode.
35
-5
46
1
°C
2.11
T4C2
The ambient temperature 1 of climate related curves for
cooling mode.
25
-5
46
1
°C
2.12
ZONE1 C-EMISSION
The type of zone1 end for cooling mode
:
0=FCU(fan coil
unit)
,
1=RAD.(radiator)
,
2=FLH(floor heating)
0
0
2
1
/
2.13
ZONE2 C-EMISSION
The type of zone2 end for cooling mode
:
0=FCU(fan coil
unit)
,
1=RAD.(radiator)
,
2=FLH(floor heating)
0
0
2
1
/
3.1
HEAT MODE
Enable or disable the heating mode
1
0
1
1
/
3.2
t_T4_FRESH_H
The refresh time of climate related curves for heating
mode
0.5
0.5
6
0.5
hours
3.3
T4HMAX
The maximum ambient operating temperature for heating
mode
25
20
35
1
°C
3.4
T4HMIN
The minimum ambient operating temperature for heating
mode
-15
-25
30
1
°C
3.5
dT1SH
The temperature difference for starting the unit (T1)
5
2
20
1
°C
3.6
dTSH
The temperature difference for starting the unit (Ta)
2
1
10
1
°C
3.7
t_INTERVAL_H
The compressor start time interval
5
5
60
1
MIN
3.8
T1SETH1
The setting temperature 1 of climate related curves for
heating mode
35
25
65
1
°C
3.9
T1SETH2
The setting temperature 2 of climate related curves for
heating mode
28
25
65
1
°C
3.10
T4H1
The ambient temperature 1 of climate related curves for
heating mode
-5
-25
35
1
°C
3.11
T4H2
The ambient temperature 2 of climate related curves for
heating mode
7
-25
35
1
°C
3.12
ZONE1 H-EMISSION
The type of zone1 end for heating mode
:
0=FCU(fan coil
unit)
,
1=RAD.(radiator)
,
2=FLH(floor heating)
1
0
2
1
/
3.13
ZONE2 H-EMISSION
The type of zone2 end for heating mode
:
0=FCU(fan coil
unit)
,
1=RAD.(radiator)
,
2=FLH(floor heating)
2
0
2
1
/
3.14
t_DELAY_PUMP
the time that the compressor has run before starting the
pump.
2
0.5
20
0.5
MIN
4.1
T4AUTOCMIN
The minimum operating ambient temperature for cooling in
auto mode
25
20
29
1
°C
4.2
T4AUTOHMAX
The maximum operating ambient temperature for heating
in auto mode
17
10
17
1
°C
5.1
WATER FLOW TEMP. Enable or disable the WATER FLOW TEMP.:0=NON,1=YES
1
0
1
1
/
5.2
ROOM TEMP.
Enable or disable the ROOM TEMP.:0=NON,1=YES
0
0
1
1
/
5.3
DOUBLE ZONE
Enable or disable the ROOM THERMOSTAT DOUBLE
ZONE:0=NON,1=YES
0
0
1
1
/
6.1
ROOM THERMOSTAT The style of room thermostat
:
0=NON,1=MODE
SET,2=ONE ZONE,3=DOUBLE ZONE
0
0
3
1
/
Содержание WSAN-YMi 101
Страница 1: ......
Страница 18: ......
Страница 35: ...Type 2 Type 2 Type 2 Type 2...
Страница 42: ...T4 Outdoor Temperatures T1S set water temperature It is curve number 9 It can be set as shown in the figure...
Страница 43: ...T4 Outdoor Temperatures T1S set water temperature It is curve number 9 It can be set as shown in the figure...
Страница 84: ...Access by pwd is reserved to qualified personnel The parameters changes may cause malfunctions...
Страница 103: ......
Страница 104: ......
Страница 105: ......
Страница 106: ......
Страница 127: ......
Страница 128: ...Via Camp Lonc 25 Z I Villapaiera 32032 Feltre BL Italy Tel 39 0439 3131 Fax 39 0439 313300 info clivet it...