About room thermostat
The ROOM THERMOSTAT is used to set whether the room
thermostat is available.
How to set the room thermostat
To set the ROOM THERMOSTAT, go to MENU > FOR
SERVICEMAN > ROOM THERMOSTAT.
Press OK.
The following page is displayed:
NOTE
The setting in the user interface should correspond to the
wiring of thermostat.
If ROOM THERMOSTAT = MODE SET, the wiring of
thermostat should follow method A.
If ROOM THERMOSTAT = ONE ZONE, the wiring of
thermostat should follow method B.
If ROOM THERMOSTAT = DOUBLE ZONE, the wiring of
thermostat should follow method C.
See chapter Electrical connections - Thermostat”)
The OTHER HEATING SOURCE is used to set whether the
backup heater, and additional heating sources like a boiler or
solar energy kit is available.
Configuration
To set the OTHER HEATING SOURCE, go to MENU > FOR
SERVICEMAN > OTHER HEATING SOURCE.
Press OK.
The following page will appear:
HOLIDAY AWAY setting
About setting
The HOLIDAY AWAY SETTING is used to set the outlet water
temperature to prevent freezing when away for holiday..
How to enter the setting
To enter the HOLIDAY AWAY SETTING, go to MENU > FOR
SERVICEMAN > HOLIDAY AWAY SETTING.
Press OK.
The following page is displayed:
The installers can set the phone number of the local dealer in
SERVICE CALL.
If the unit doesn’t work properly, call this number for help.
Configuration
To set the SERVICE CALL, go to MENU > FOR
SERVICEMAN > SERVICE CALL. Press OK.
The following page is displayed:
Use UP DOWN to scroll and set the phone number.
The maximum length of the phone number is 13 digits, if the
length of phone number is short than 12, please input *, as
shown below:
The number displayed on the user interface is the phone
number of your local dealer.
Содержание WSAN-YMi 101
Страница 1: ......
Страница 18: ......
Страница 35: ...Type 2 Type 2 Type 2 Type 2...
Страница 42: ...T4 Outdoor Temperatures T1S set water temperature It is curve number 9 It can be set as shown in the figure...
Страница 43: ...T4 Outdoor Temperatures T1S set water temperature It is curve number 9 It can be set as shown in the figure...
Страница 84: ...Access by pwd is reserved to qualified personnel The parameters changes may cause malfunctions...
Страница 103: ......
Страница 104: ......
Страница 105: ......
Страница 106: ......
Страница 127: ......
Страница 128: ...Via Camp Lonc 25 Z I Villapaiera 32032 Feltre BL Italy Tel 39 0439 3131 Fax 39 0439 313300 info clivet it...