Stata - tab 3
MENU ID
Short
description
Description
3003 Thermoregulator
40
CPYCurrent
CPY humidifier absorbed current
3003 Thermoregulator
41
CPYIstSteam
CPY humidifier output
3003 Thermoregulator
42
Supply Q Air
Supply air flow rate
3003 Thermoregulator
43
Return Q Air
Return air flow rate
3003 Thermoregulator
44
Supply temp. ctrl low power
Supply temperature control activation status for low capacities
3003 Thermoregulator
45
Max mod. damper low power
Maximum renewal for supply limit
3003 Thermoregulator
46
SetActPAmbExt
Current external/return pressure setpoint
3003 Thermoregulator
47
PressRoomExFlow
Status of the ambient pressure detector – ExFlow opt.
3003 Thermoregulator
48
Nr Extractor Run ExFlow
Number of active extractors – ExFlow option
3003 Thermoregulator
49
ExFlow Modulation
External damper modulation associated with ExFlow opt.
3101 Circuit C1 Stata
1100 CMP1 starts
Compressor 1 start-ups
3101 Circuit C1 Stata
1101 CMP2 starts
Compressor 2 start-ups
3101 Circuit C1 Stata
1102 CMP3 starts
Compressor 3 start-ups
3101 Circuit C1 Stata
1104 Source starts
Source motor start-ups
3101 Circuit C1 Stata
1105 Hours Comp.1
Compressor 1 hours
3101 Circuit C1 Stata
1106 Hours Comp.2
Compressor 2 hours
3101 Circuit C1 Stata
1107 Hours Comp.3
Compressor 3 hours
3101 Circuit C1 Stata
1108 HoursScrew
Screw compressor hours
3101 Circuit C1 Stata
1109 HoursSource
Source motor hours
3101 Circuit C1 Stata
1110 Total steps
Total amount of active steps on the circuit
3101 Circuit C1 Stata
1111 Comp.1 status
0=Free 1=Active 2=Timed 3=Not enabled
3101 Circuit C1 Stata
1112 Comp.2 status
0=Free 1=Active 2=Timed 3=Not enabled
3101 Circuit C1 Stata
1113 Comp.3 status
0=Free 1=Active 2=Timed 3=Not enabled
3101 Circuit C1 Stata
1114 Current cap.
Capacity currently employed on the circuit
3101 Circuit C1 Stata
1115 Requested cap.
Capacity requested on the circuit
3101 Circuit C1 Stata
1116 Pressure ratio
Compression ratio status (1+Hp/1+LP)
3101 Circuit C1 Stata
1117 FANPreAlarm
Status of the maximum ventilation pre-alarm in progress 0=Off
1=On
3101 Circuit C1 Stata
1118 Defrost delay
Current value of the countdown towards the cycle inversion due to
defrosting. (defrosting starts when the value reaches zero)
3101 Circuit C1 Stata
1119 Defrost status
Indicates the defrosting status 0=DfrOff (Cycle inversion phase for
defrosting phase NOT active) 1=DfrON (Cycle inversion phase for
defrosting phase ACTIVE)
3101 Circuit C1 Stata
1120 HWErr
0=Off 1=On_Hardware error of the POL94U module that does not
preclude the possibility of moving the valve or closing it. Possible
causes: anomalous voltage values in the valve motor
3101 Circuit C1 Stata
1121 BlckingHWErr
0=Off 1=On_Hardware error of the POL94U module that prevents
the electronic valve from moving. Possible causes: UPS not availa-
ble, wrong POL94U Bios, HW POL94U Error, Disconnected EEV
Motor, calibration error associated with configuration parameters.
3101 Circuit C1 Stata
1122 FailSafeSta
0=Off 1=On_Active block status
3101 Circuit C1 Stata
1123 UPSNotAval 0=Off
1=On_UPS
failure
3101 Circuit C1 Stata
1124 CircWarning
Status associated with minor alarm on the circuit
3101 Circuit C1 Stata
1125 CircBlock
Status associated with circuit block alarm
3101 Circuit C1 Stata
1126 ThTempDischarge Theoretical
discharge
temperature
3102 Circuit C1 -IO Stata
-
T.DischargeC1_B1:AI-985 Compressor 1 discharge temperature
Содержание CSRN-XHE2 Series
Страница 1: ...CSRN XHE2 49 4 110 4 R 410A M07V40B13 07 11 20 MANUAL FOR INSTALLATION USE AND MAINTENANCE...
Страница 75: ...Dimensional drawings 75...
Страница 77: ...Dimensional drawings 77...
Страница 79: ...Dimensional drawings 79...
Страница 81: ...Dimensional drawings 81...
Страница 83: ...Dimensional drawings 83...
Страница 85: ...Dimensional drawings 85...
Страница 87: ...Dimensional drawings 87...
Страница 89: ...Dimensional drawings 89...
Страница 91: ...Dimensional drawings 91...