climecon.fi
14
Lämmittäjänkatu 4 A, 00880 Helsinki, FINLAND · Tel. +358 (0)20 198 6600
© Climecon
Close the SlideSafe safety lock by first lifting the hand knobs to their
upper position and then retightening them.
Install all grease separators back into the hood.
Install the outermost grease separators first
and the grease separator second from the left
as the last.
Attach the UV lamp’s electrical
connector (quick connector) to
the hood’s ceiling and tighten it
by turning it clockwise.
Attach the new UV lamp to
the brackets and tighten the
hand knobs by turning them
clockwise.
Replace the UV lamp. Only
Climecon’s UV lamps can be
used in the CleanMaster® sys-
tem. Order a new lamp through
Climecon’s customer service.
In uncertain cases, always contact
Climecon’s customer service,
tel. +358 (0)20 1986 600.
10. Changing the UV lamp
4
8
12
9
10
11
5
6
7
2
3
ULTRAVIOLET RADIATION HAZARD
Please deliver your old UV
lamp to a collection point
for fluorescent tubes.
Twist the hand knobs of the UV
lamp brackets counterclockwise
and detach the UV lamp from the
brackets.
First, disconnect the leftmost grease separator and
then the others.
Disconnect the UV lamp’s elec-
trical connector (quick connec-
tor) from the hood ceiling by
turning it counterclockwise.
Switch the system off before performing
any maintenance actions!
Open the SlideSafe safety lock by loosening the hand knobs and
lowering them to their lower position.
Move the left grease separator
further to the left.
OFF
1
WEAR PROTECTIVE EYEWEAR DURING
INSTALLATION AND MAINTENANCE