1.
Attach the UV lamp carefully to the fastenings in the hood’s grease chamber.
NOTE! Centre the lamp’s blue plastic parts to the fastenings. Tighten the fasten-
ings using fixing screws.
2.
Connect the quick connector of the lamp’s power cable to its counterpart on the
hood’s ceiling. Rotate the connector’s locking ring.
NOTE! Attach the instruction labels (included in the delivery) for changing the UV
lamp and maintaining the hood in a visible place near the CCM control unit.
3.
Attach the UV lamp’s power cords to the holes in the fastenings with cable ties
and roll up any extra cords so that they do not lie in the grease.
NOTE! Do not attach the cords directly to the lamp!