1.
Connector for the external controller
2.
ModBUS connection point
3.
Filter (to be replaced as necessary)
4.
Fan (check functionality during maintenance)
5.
Electrical supply 230 V LN + protective earth
6.
Controller with a screen, see sperate instructions:
Climecon CleanMaster controller’s instructions:
climecon.fi/clm
The screen also displays the amount of air (l/s)
7.
Automation points, see separate instructions:
Automation instructions climecon.fi/clm
8.
UV light switch
9.
Differential pressure transmitter, automatic calibration*
You can also view the con-
trol device by opening the
hatch below the hood.
NOTE! Remember to take
into account the loose cable
needed for opening the
hatch.
1.
Exhaust chamber’s measuring connection
(check the K value from the label inside the hood)
2.
UV-approved grease separators
3.
Measuring connection between the supply air chamber
and control air (check the K value from the label inside
the hood)
4. CleanMaster quick guide
CleanMaster features integrated technology for the UV use. A separate control device is not needed. The hood
is electrified by connecting the power cord to the integrated control device on top of the hood. The casing can
also be accessed from below the hood by opening the quick latches, which allows the hinged cover with the
control device to open. The light has a separate cord that needs to be connected to the lighting group.
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
1.
Supply point for the UV light and the SlideSafe switch*
2.
Pressure transmitter*
3.
Exhaust air
4.
Integrated control device
5.
Carrying points M8 in the corners (also in the middle
for the larger size classes, Z iron included to facilitate
mounting)
6.
Easily removable supply air slats for maintenance
7.
Supply air
8.
Grommets for the control device (with strain reliefs)
9.
Climecon OptiLUMO LED light*
10.
End wall (removable for units with several modules)
Danger of electric shock!
Electricity supply to the control device
NOTE! Electrical connections may only be made by a professional electrician.
- The hood has to be electrified through the safety switch, which is visible near the hood and has been named
- The control device’s switching power is max. 400 W
- The light is connected to the light group (connection cable as factory equipment)
Always switch the system off before performing any maintenance!
2.
3.
4.
5.
6.
7.
8.
9.
1.
The control device’s hatch can be opened by
unscrewing the 4 screws in the hatch
3.
2.
1.
*connected at the factory
OFF