Page 2
Ultra Classic (VT) Series
GENERAL INFORMATION
Storage
CAUTION: DO NOT store or install units in
corrosive environments or in locations subject to
temperature or humidity extremes (e.g., attics,
garages, rooftops, etc.). Corrosive conditions and
high temperature or humidity can significantly
reduce performance, reliability, and service life.
Always move units in an upright position. Tilting
units on their sides may cause equipment damage.
Equipment should be stored in its shipping carton in a
clean, dry area. Store units in an upright position at all
times. Stack vertical units a maximum of 2 units high.
DO
NOT remove equipment from shipping cartons until
equipment is required for installation.
Unit Protection
Cover units on the job site with either shipping cartons,
vinyl film, or an equivalent protective covering. Cap the
open ends of pipes stored on the job site. In areas where
painting, plastering, or spraying has not been completed,
all due precautions must be taken to avoid physical
damage to the units and contamination by foreign material.
Physical damage and contamination may prevent proper
start-up and may result in costly equipment cleanup.
Examine all pipes, fittings, and valves before installing
any of the system components. Remove any dirt or trash
found in or on these components.
Inspection
Upon receipt of the equipment, carefully check the
shipment against the bill of lading. Make sure all units
have been received. Inspect the carton or crating of
each unit, and inspect each unit for damage. Assure
the carrier makes proper notation of any shortages or
damage on all copies of the freight bill and he completes
a common carrier inspection report. Concealed damage
not discovered during unloading must be reported to the
carrier within 15 days of receipt of shipment. If not filed
within 15 days, the freight company can deny the claim
without recourse.
Note: It is the responsibility of the
purchaser to file all necessary claims with the carrier.
Notify the ClimateMaster Customer Service of all damage
within fifteen (15) days of shipment.
Introduction
ClimateMaster UltraClassic Geothermal Heat Pump units
are typically installed in a floor level closet, basement,
or in a small mechanical room. The installation site
chosen for these units must allow adequate clearance for
maintenance and servicing of the unit without its removal
from the installation location.
Model Nomenclature
CONTROLS:
048
G = 208V, 230V/1PH/60Hz
060
072
SSS = CXM w/ECM
VT = ULTRA CLASSIC VERTICAL
VOLTAGE:
SIZE:
042
036
SERIES:
V
1
T
2
0
3
3
4
G
6
6
5
S
7
S
8
S
9
D = RESIDENTIAL CLASS
LT = LEFT RETURN, TOP DISCHARGE
REVISION CODE:
AIR FLOW CONFIGURATION:
HEAT EXCHANGER OPTIONS:
D
12
10
L T
11
13
A S
14
CABINET:
J
15
J = CURRENT REVISION SIZE 036
H = CURRENT REVISION SIZES 042-072
B = COPPER WATER COIL,
W/HOT WATER GENERATOR, E-COATED AIR COIL
A = COPPER WATER COIL, E-COATED AIR COIL
J = CUPRO-NICKEL WATER COIL, E-COATED AIR COIL
K = CUPRO-NICKEL WATER COIL,
W/HOT WATER GENERATOR, E-COATED AIR COIL
S = STANDARD
RT = RIGHT RETURN, TOP DISCHARGE
Rev.: 04/15/04D