Installation Manual 

97B0055N03

Rev.: 2/4/13

ATC32U01 iGate

 Communicating, 

Programmable Thermostat

Table of Contents

Section Title 

Page

  

Safety/Installation 

Considerations  3

1.0 

User Menu Settings 

  4

2.0 

Installer Menu Settings 

  6

 

2.1 

Installer Menu Settings Access 

  6

 2.2 

Thermostat 

Confi guration 

  6

3.0 System 

Confi guration 

  7

 3.1 

Airfl ow Selection 

  7

 3.2 

Option 

Selection 

 7

 3.3 

Unit 

Confi guration 

  8

 

3.4  

Pump Confi guration 

  8

 3.5 

Valve 

Confi guration 

  9

 3.6 

Multi-Unit 

Confi guration 

  9

4.0 Accessory 

Confi guration 

  10

 

4.1  

Air Filter 

  10

 4.2 

 

Humidifi er 

  10

 

4.3  

UV Lamp 

  10

Caution:

These instructions are intended to be used by the installer or service personnel.  End users are NOT advised to change or 
modify any of these settings.  Doing so may cause the equipment to stop working properly and/or may void the warranty on 
both the thermostat and the equipment.

Section Title 

Page

 

4.4  

Air Cleaner 

  10

5.0 

Input Dealer Information 

  11

6.0 Humidity 

Confi guration 

  11

7.0 Temperature 

Algorithm 

 

11

8.0 

Demand Reduction Confi guration    11

9.0 Service 

Mode 

 

12

 9.1 

Manual 

Operation 

 12

 9.2 

Control 

Diagnostics 

 12

 9.3 

Dipswitch 

Confi guration 

  13

 9.4 

Fault 

History 

 13

 

9.5 

Clear Fault History 

  14

 9.6 

Multi-Unit 

Diagnostics 

 14

 

9.7 

Multi-Unit Fault Information 

  15

10.0 Restore 

Defaults 

 

15

11.0 Revision 

History 

16

Содержание ATC32U01 iGate

Страница 1: ...10 4 3 UV Lamp 10 Caution These instructions are intended to be used by the installer or service personnel End users are NOT advised to change or modify any of these settings Doing so may cause the e...

Страница 2: ...This page was intentionally left blank...

Страница 3: ...ct airflow from supply registers In areas with poor air circulation such as behind a door or in an alcove II THERMOSTAT INSTALLATION 1 Turn off all power to unit 2 If an existing thermostat is being r...

Страница 4: ...f 70 F your thermostat will not call for heating until the temperature is 69 F Adjust the Differential setting using the up down arrow buttons Navigate between Differentials using the left right arrow...

Страница 5: ...mation then press and hold the right arrow for 5 seconds 1 4 2 DEMO MODE OPERATION Control Demo Mode operation parameters from the Demo Operation screen shown below DEMO OPERATION OUTDOOR FAN AUTO 78...

Страница 6: ...multi stage compressor applications 2 0 Installer Menu Settings 2 1 INSTALLER MENU SETTINGS ACCESS The Installer Settings can be accessed at any time from the Main Operating screen by holding the up d...

Страница 7: ...be present if the connected communicating control is configured for No Loop Configuration OTHER 3 1 AIRFLOW SELECTION Adjust the airflow settings for each system operating mode using the up down arro...

Страница 8: ...mum Heat LWT valid range based on specific model refer to model IOM Minimum Cool LWT valid range based on specific model refer to model IOM NOTE Refer to section 3 6 3 for multi unit configuration ins...

Страница 9: ...3 for multi unit configuration instructions VARIABLE SPD INTERNAL PUMP CONFIGURATION PUMP CONTROL FIXED HEATING STAGE 1 60 COOLING STAGE 2 75 COOLING STAGE 1 50 COOLING STAGE 2 70 PREVIOUS SELECT 3 5...

Страница 10: ...to remind the user to change the air filter after the selected time has passed Adjust the Air Filter Reminder settings using the up down arrow buttons Press the center button to save changes Cumulativ...

Страница 11: ...nergized until the demand is fully satisfied see NOTE 1 Differential This logic will only use temperature differential to determine the appropriate heating or cooling stages for operation This logic w...

Страница 12: ...COMM OUTPUT OFF O COMM OUTPUT OFF G COMM OUTPUT OFF H COMM OUTPUT OFF DH COMM OUTPUT OFF ECM AIRFLOW 0 PUMP SPEED 0 TEST MODE OFF SELECT OPTION PREVIOUS SELECT 9 2 CONTROL DIAGNOSTICS Control Diagnos...

Страница 13: ...T OFF 3 OFF HWG SP 125 4 OFF HWG DISABLED JW3 LT1 SETTING WELL PREVIOUS 9 4 FAULT HISTORY Fault History mode displays the five most recent stored fault codes for the connected communicating control DX...

Страница 14: ...CC Y2 Y2 CO RV W W ACC1 O O OUTPT ACC2 G G FAN AL1 H H HWG EH1 OVR DH PUMP EH2 PREVIOUS FAULT CONFG CONDITIONS LT1 LOW WATER TEMP HEAT 1 11 11 AM 11 14 S1 S2 S3 1 ON 1 ON 1 ON 2 ON 2 ON 2 OFF 3 ON 3 O...

Страница 15: ...its are connected to one thermostat UNLIKE Mult Unit Diagnostics the service personnel views each units fault information by selecting the next option 10 0 Restore Defaults The thermostat will reset a...

Страница 16: ...contained herein are not express warran ties and do not form the basis of any bargain between the parties but are merely ClimateMaster s opinion or commendation of its products The management system...

Отзывы: