AT C 3 2 U 0 1   C o m m u n i c a t i n g ,   P r o g r a m m a b l e   T h e r m o s t a t   -   I O M

R e v. :   4   F e b . ,   2 0 1 3

THERMOSTAT

CONFIGURATION

PROGRAMMABLE

NON PROGRAMMABLE

NIGHT SETBACK

SELECT OPTION   

 PREVIOUS                                          SAVE 

INSTALLER SETTINGS

THERMOSTAT CONFIG

SYSTEM CONFIG

ACCESSORY CONFIG

INPUT DEALER INFO

HUMIDITY CONFIG

TEMPERATURE ALGORITHM

DEMAND REDUCTION CNFG

SERVICE MODE

RESTORY DEFAULTS

ATC32U01

SELECT OPTION   

 PREVIOUS

SYSTEM CONFIGURATION

AIRFLOW SELECTION

OPTION SELECTION

UNIT CONFIG                                           TE026

PUMP CONFIGURATION

SELECT OPTION   

 PREVIOUS                                          SAVE 

AIRFLOW SELECTION

                                                                      CFM

HEAT STAGE 1                                              600

HEAT STAGE 2                                              750 

AUXILIARY HEAT                                          850

EMERGENCY HEAT                                      850

COOL STAGE 1                                             525

COOL STAGE 2                                             700

COOL DEHUMID 1                                        425

COOL DEHUMID 2                                        550

CONTINUOUS FAN                                       350

HEAT OFF DELAY                                           60

COOL OFF DELAY                                          30

 PREVIOUS                                             NEXT 

3.0  System Confi guration

Use the System Confi guration option on the start-up screen 
to adjust critical equipment settings.

The System Confi guration information will be automatically 
obtained from each communicating control in the system.

Note 1: 

The Airfl ow Selection menu (section 3.1) will not be 

present if the connected communicating control is confi gured 
for No Blower.

Note 2: 

The Pump Confi guration menu (section 3.4) will 

not be present if the connected communicating control is 
confi gured for No Loop Confi guration (OTHER).

Note 3: 

The Valve Confi guration menu (section 3.5) will 

not be present if the connected communicating control is 
confi gured for No Loop Confi guration (OTHER). 

3.1 AIRFLOW 

SELECTION

Adjust the airfl ow settings for each system operating mode 
using the up/down arrow buttons.  Press the center button to 
select each item.

• Airfl ow Settings (defaults stored in control) 

valid range:  obtained from control (in 25 CFM 

increments)

•  Blower Off Delay (default 60 seconds) 

– valid 

range:  0 to 255 seconds (in 5 second increments)

NOTE 1: 

 The Airfl ow Settings will only be present if the 

connected communicating control is confi gured for ECM 
blower.

NOTE 2:

  If multiple units are connected to one thermostat, 

refer to section 3.6 for unit selection.

3.2 OPTION 

SELECTION

This option allows the confi guration of heat pump options to 
be modifi ed.

Adjust the Option settings using the up/down arrow buttons.  
Press the center button to select each item.

•  Motorized Valve (defaults stored in control)

 – 

valid range:  Off, On “On” delays compressor start 
until the valve is fully open. 

NOTE:

  “Motorized Valve” used here refers to a two-position 

motorized water valve, not to be confused with the modulating 
motorized water valve found in the LOOP CONFIG.

2.2.3 PROGRAMMING

Adjust the Programming options using the up/down arrow 
buttons.  Press the center button to save changes.
 

• Programmable 

(default)

 – enables 7-day    

  

programming

 

• Non-Programmable

 – disables 7-day programming

 

• Night 

Setback

 – enables night setback 

  

programming

NOTE

:  When the thermostat is confi gured for non-

programmable mode, the Display Date and Time setting 
defaults to NO.

Содержание ATC32U01 iGate

Страница 1: ...10 4 3 UV Lamp 10 Caution These instructions are intended to be used by the installer or service personnel End users are NOT advised to change or modify any of these settings Doing so may cause the e...

Страница 2: ...This page was intentionally left blank...

Страница 3: ...ct airflow from supply registers In areas with poor air circulation such as behind a door or in an alcove II THERMOSTAT INSTALLATION 1 Turn off all power to unit 2 If an existing thermostat is being r...

Страница 4: ...f 70 F your thermostat will not call for heating until the temperature is 69 F Adjust the Differential setting using the up down arrow buttons Navigate between Differentials using the left right arrow...

Страница 5: ...mation then press and hold the right arrow for 5 seconds 1 4 2 DEMO MODE OPERATION Control Demo Mode operation parameters from the Demo Operation screen shown below DEMO OPERATION OUTDOOR FAN AUTO 78...

Страница 6: ...multi stage compressor applications 2 0 Installer Menu Settings 2 1 INSTALLER MENU SETTINGS ACCESS The Installer Settings can be accessed at any time from the Main Operating screen by holding the up d...

Страница 7: ...be present if the connected communicating control is configured for No Loop Configuration OTHER 3 1 AIRFLOW SELECTION Adjust the airflow settings for each system operating mode using the up down arro...

Страница 8: ...mum Heat LWT valid range based on specific model refer to model IOM Minimum Cool LWT valid range based on specific model refer to model IOM NOTE Refer to section 3 6 3 for multi unit configuration ins...

Страница 9: ...3 for multi unit configuration instructions VARIABLE SPD INTERNAL PUMP CONFIGURATION PUMP CONTROL FIXED HEATING STAGE 1 60 COOLING STAGE 2 75 COOLING STAGE 1 50 COOLING STAGE 2 70 PREVIOUS SELECT 3 5...

Страница 10: ...to remind the user to change the air filter after the selected time has passed Adjust the Air Filter Reminder settings using the up down arrow buttons Press the center button to save changes Cumulativ...

Страница 11: ...nergized until the demand is fully satisfied see NOTE 1 Differential This logic will only use temperature differential to determine the appropriate heating or cooling stages for operation This logic w...

Страница 12: ...COMM OUTPUT OFF O COMM OUTPUT OFF G COMM OUTPUT OFF H COMM OUTPUT OFF DH COMM OUTPUT OFF ECM AIRFLOW 0 PUMP SPEED 0 TEST MODE OFF SELECT OPTION PREVIOUS SELECT 9 2 CONTROL DIAGNOSTICS Control Diagnos...

Страница 13: ...T OFF 3 OFF HWG SP 125 4 OFF HWG DISABLED JW3 LT1 SETTING WELL PREVIOUS 9 4 FAULT HISTORY Fault History mode displays the five most recent stored fault codes for the connected communicating control DX...

Страница 14: ...CC Y2 Y2 CO RV W W ACC1 O O OUTPT ACC2 G G FAN AL1 H H HWG EH1 OVR DH PUMP EH2 PREVIOUS FAULT CONFG CONDITIONS LT1 LOW WATER TEMP HEAT 1 11 11 AM 11 14 S1 S2 S3 1 ON 1 ON 1 ON 2 ON 2 ON 2 OFF 3 ON 3 O...

Страница 15: ...its are connected to one thermostat UNLIKE Mult Unit Diagnostics the service personnel views each units fault information by selecting the next option 10 0 Restore Defaults The thermostat will reset a...

Страница 16: ...contained herein are not express warran ties and do not form the basis of any bargain between the parties but are merely ClimateMaster s opinion or commendation of its products The management system...

Отзывы: