MULTI-UNIT OPTION SELECTION

 

In section 3.2, when an installer selects “Option 
Selection” from the System Confi guration menu, 
the installer may choose the unit to confi gure 
by the last 4 digits of its serial number from the 
following screen.

AIRFLOW SELECTION

TT026                                       S N - - - - - 1 2 3 4

TT026                                       S N - - - - - 5 6 7 8

TT038                                       S N - - - - - 9 0 1 2

 PREVIOUS                                        SELECT 

OPTION SELECTION

TT026                                       S N - - - - - 1 2 3 4

TT026                                       S N - - - - - 5 6 7 8

TT038                                       S N - - - - - 9 0 1 2

 PREVIOUS                                        SELECT 

 

3.6.3 

MULTI-UNIT, UNIT, PUMP, & VALVE 

CONFIGURATION

 To 

confi gure Unit, Pump, and Valve options in 

sections 3.3-3.5, the thermostat must be  
connected to only one unit at a time.

 3.6.1 

MULTI-UNIT 

AIRFLOW 

SELECTION

 

In section 3.1, when an installer selects “Airfl ow 
Selection” from the System Confi guration menu, 
the installer may choose the unit to confi gure 
by the last 4 digits of its serial number from the 
following screen.

4.0  Accessory Confi guration

A service message will fl ash at the top of the Main screen 
when a service timer expires to alert the user that it is time to 
service these options. Refer to DXM2 AOM for instructions on 
confi guring DIP switches to confi gure accessories. Follow the 
instructions below to set service timers.

4.1 AIR 

FILTER

This feature displays an alert to remind the user to change 
the air fi lter after the selected time has passed.

Adjust the Air Filter Reminder settings using the up/down 
arrow buttons.  Press the center button to save changes.
 

•  Cumulative Run Time (default Off) – 

valid range:  

 

 

Off, 400 to 3600 hours (in 100 hour increments

)

 

•  Calendar Time (default Off) – 

valid range:  Off, 3 

 

 

to 48 months (in 3 month increments)

4.2 HUMIDIFIER

This feature displays an alert to remind the user to change 
the humidifi er pad after the selected time has passed.

Adjust the Humidifi er Reminder settings using the up/down 
arrow buttons.  Press the center button to save changes.

 

•  Cumulative Run Time (default Off) 

– valid range:  

 

 

Off, 400 to 3600 hours (in 100 hour increments)

 

•  Calendar Time (default Off) 

– valid range:  Off, 3 

 

 

to 24 months (in 3 month increments)

 

4.3 UV 

LAMP

This feature displays an alert to remind the user to change 
the UV lamps after the selected time has passed.

Adjust the UV Lamp Reminder settings using the up/down 
arrow buttons.  Press the center button to save changes.
 

•  Cumulative Run Time (default Off) 

– valid range:  

 

 

Off, 400 to 3600 hours (in 100 hour increments)

 

•  Calendar Time (default Off)

 – valid range:  Off, 3 

 

 

to 48 months (in 3 month increments)

4.4 AIR 

CLEANER

This feature displays an alert to remind the user to clean the 
fi lter(s) after the selected time has passed.

INSTALLER SETTINGS

THERMOSTAT CONFIG

SYSTEM CONFIG

ACCESSORY CONFIG

INPUT DEALER INFO

HUMIDITY CONFIG

TEMPERATURE ALGORITHM

DEMAND REDUCTION CNFG

SERVICE MODE

RESTORY DEFAULTS

ATC32U01

SELECT OPTION   

 PREVIOUS

Содержание ATC32U01 iGate

Страница 1: ...10 4 3 UV Lamp 10 Caution These instructions are intended to be used by the installer or service personnel End users are NOT advised to change or modify any of these settings Doing so may cause the e...

Страница 2: ...This page was intentionally left blank...

Страница 3: ...ct airflow from supply registers In areas with poor air circulation such as behind a door or in an alcove II THERMOSTAT INSTALLATION 1 Turn off all power to unit 2 If an existing thermostat is being r...

Страница 4: ...f 70 F your thermostat will not call for heating until the temperature is 69 F Adjust the Differential setting using the up down arrow buttons Navigate between Differentials using the left right arrow...

Страница 5: ...mation then press and hold the right arrow for 5 seconds 1 4 2 DEMO MODE OPERATION Control Demo Mode operation parameters from the Demo Operation screen shown below DEMO OPERATION OUTDOOR FAN AUTO 78...

Страница 6: ...multi stage compressor applications 2 0 Installer Menu Settings 2 1 INSTALLER MENU SETTINGS ACCESS The Installer Settings can be accessed at any time from the Main Operating screen by holding the up d...

Страница 7: ...be present if the connected communicating control is configured for No Loop Configuration OTHER 3 1 AIRFLOW SELECTION Adjust the airflow settings for each system operating mode using the up down arro...

Страница 8: ...mum Heat LWT valid range based on specific model refer to model IOM Minimum Cool LWT valid range based on specific model refer to model IOM NOTE Refer to section 3 6 3 for multi unit configuration ins...

Страница 9: ...3 for multi unit configuration instructions VARIABLE SPD INTERNAL PUMP CONFIGURATION PUMP CONTROL FIXED HEATING STAGE 1 60 COOLING STAGE 2 75 COOLING STAGE 1 50 COOLING STAGE 2 70 PREVIOUS SELECT 3 5...

Страница 10: ...to remind the user to change the air filter after the selected time has passed Adjust the Air Filter Reminder settings using the up down arrow buttons Press the center button to save changes Cumulativ...

Страница 11: ...nergized until the demand is fully satisfied see NOTE 1 Differential This logic will only use temperature differential to determine the appropriate heating or cooling stages for operation This logic w...

Страница 12: ...COMM OUTPUT OFF O COMM OUTPUT OFF G COMM OUTPUT OFF H COMM OUTPUT OFF DH COMM OUTPUT OFF ECM AIRFLOW 0 PUMP SPEED 0 TEST MODE OFF SELECT OPTION PREVIOUS SELECT 9 2 CONTROL DIAGNOSTICS Control Diagnos...

Страница 13: ...T OFF 3 OFF HWG SP 125 4 OFF HWG DISABLED JW3 LT1 SETTING WELL PREVIOUS 9 4 FAULT HISTORY Fault History mode displays the five most recent stored fault codes for the connected communicating control DX...

Страница 14: ...CC Y2 Y2 CO RV W W ACC1 O O OUTPT ACC2 G G FAN AL1 H H HWG EH1 OVR DH PUMP EH2 PREVIOUS FAULT CONFG CONDITIONS LT1 LOW WATER TEMP HEAT 1 11 11 AM 11 14 S1 S2 S3 1 ON 1 ON 1 ON 2 ON 2 ON 2 OFF 3 ON 3 O...

Страница 15: ...its are connected to one thermostat UNLIKE Mult Unit Diagnostics the service personnel views each units fault information by selecting the next option 10 0 Restore Defaults The thermostat will reset a...

Страница 16: ...contained herein are not express warran ties and do not form the basis of any bargain between the parties but are merely ClimateMaster s opinion or commendation of its products The management system...

Отзывы: