Pas sen ger Com part ment Con nec tions (Con tin ued)
Aux il iary A with Se lecta ble Out put Type
The Auxiliary A output (GRAY/VIOLET wire) can be programmed as either pulsed, latched
or timed and can be programmed to operate only when the system is disarmed (e.g., for use as
a remote trunk release). Auxiliary A output is activated by pressing the
button on the
remote control. The factory setting is pulsed output (0.5 second ground). The latched output
stays at ground until the
button is pressed a second time, and the timed output stays at
ground for any selected duration between one second and four minutes. See
Installer-Programmable Features
on page 16 for information on programming the output type
and/or disabling operation while the system is armed.
Aux il iary B with Se lecta ble Out put Type and AutoAc ti va tion
The Auxiliary B output (GRAY/BLUE wire) can be programmed as either pulsed, latched or
timed. It can also be programmed to automatically activate every time the system is remotely
armed. The output is activated by pressing the
button on the remote. Current is limited to
0.25 amp. AutoActivation is perfect when programmed as a timed-output to close the power
windows and sunroof on vehicles that have an all-close feature (see the
Window Control
section at
the end of this manual for more information on wiring this feature). See
Installer-Programmable
Features
on page 16 for more information on programming output type and/or enabling the
AutoActivation feature.
Win dow Con trol
If the windows can be closed using a key in the door of the car then an optional relay can be
added to automatically close the power windows or the sunroof.
Auto matic Win dow/Sun roof Clo sure (re quires op tional re lay)
If the door key can close the power windows/sunroof, you can make them automatically close
upon remote arming:
1. Find the wire that shows 12V or (-) when the key is held to lock in the door
cylinder.
2. Tap a wire in to this wire and connect to terminal 30 of the relay.
3. If the wire shows (-) when the key is turned, connect terminal 87 to (-). If the wire shows
+12V when the key is turned, connect terminal 87 to 12V.
4. Connect the GRAY/BLUE wire of the alarm terminal 85.
5. C12V to terminal 86.
8. Turn on the
AutoActivate timed accessory upon remote arming
feature as noted in the
installation manual for the alarm under Installer-Programmable Features.
8. Set the timer duration to proper time interval with two seconds added to that time
interval.
10