Installation Guide / SolarRoof Terracotta Tile
10
Code-Compliant Planning and Installation Guide V 1.0 - Complying with AS/NZS1170.2-2011 AMDT 2-2016
- Assess the number of modules in the vertical direction using the module height plus at least 18mm between modules
(please check the installation manual of the solar module manufacturer).
- Assess the Number of modules in the horizontal direction using the module width plus 18 mm (20 mm if using
Universal Clamps) between the modules. Note: The standard end clamp will also add 20 mm (except for dual end
clamps) on each side to the space required.
- Assess the horizontal spacing of the Roof Hooks.
- Assess the vertical spacing of the Roof Hooks = approx. 1⁄2 to 3⁄4 of module height.
- Always check the installation manual of the PV-Module you use in order to determine the allowed fixing points on
the module frame.
Installation Instructions
- Installation Instructions -