4
Code-Compliant Planning and Installation Guide V 1.0 - Complying with AS/NZS1170.2-2011 AMDT 2-2016
- Planning -
Determine Roof slope
The PV-ezRack® SolarRoof system can be used for roof slopes up to 60°. Please verify that the Installation site roof
slope is between 0° and 60°.
Determine the Installation Area of Roof
Please refer to the generic notes 29, 30 and 32 of Certification Letter to determine the installation area based on
building height, length, and width. Please be aware at certain building conditions there is an Exclusion Zone for flush
installation, which is the minimum distance between PV solar panel and roof edge of "2s", where "s" is the gap between
the underside of the panel and the roof surface.
Verify Rafter Properties of Building
Please verify rafter properties of building, which could affect the interface spacing.
Timber Rafters:
Tile Roof interface spacing tables are based on a minimum depth into F7 (Pine) timber of 25mm.
Metal Rafters:
Tile Roof interface spacing tables are based on 1.9mm thick Steel Purlins G450 or equivalent. For more information,
please refer to Note 3 and 4 of the Certification Letter.
ER-I-01, ER-I-01/CS
ER-I-23
ER-I-01/EZC/ECO
ER-I-26
ER-I-51
ER-I-41/EZC/ ECO
ER-I-61/EZC/ECO