Installation Guide / SolarRoof Terracotta Tile
5
Code-Compliant Planning and Installation Guide V 1.0 - Complying with AS/NZS1170.2-2011 AMDT 2-2016
- Planning -
Determine the Maximum Rail Support Spacing
Please refer to the interface spacing tables in the Certification Letter appended in this document.
If a project specific Certification Letter has been provided, please refer to the support spacing in this letter.
Verify Maximum Rail End Overhang
Rail end overhang should be not over 40% of the interface spacing. For example, if the interface spacing is 1500mm,
the Rail end overhang can be up to 600mm only.
Acquire PV Modules Clamping Zone Information
It is recommended to acquire PV modules clamping zone information from PV modules manufacturer, which can help
to plan interface, and rail position and orientation.
Assembly Drawing
Please refer below for a case example of an assembly drawing of Clenergy Tile Bracket, ER-I-01, with Boral French
Terracotta Tiles:
For more information, refer to Installation Instruction on page 10.