6. Press the Zone Setting numbers for quick
operation (Figure 42). The three preset zones are
factory configured with different solution flow rates
and down pressures.
FIG. 42
To change the Zone Settings for a specific
scrubbing application, configure the new zone
settings and press and hold the zone button until it
blinks three times to save new zone setting.
The zone settings can configure the following
controls:
- Down pressure rate
- Solution flow rate
- Quiet-Mode on or off (option)
- ec-H2O mode on or off (option)
- Severe Environment mode on or off (option).
NOTE: The severe environment mode and ec-H2O
mode cannot be configured together.
7. If a machine fault is detected during operation, the
service indicator will light up and begin flashing
(Figure 43). See SERVICE INDICATOR CODES.
If the ec-H2O system detects a fault during
operation, the ec-H2O icon will turn or blink red.
See SERVICE INDICATOR CODES.
FIG. 43
ec-H2O INDICATOR
CONDITION
Solid blue
Normal operation
Blinking blue/red
Water conditioning cartridge
expired. Replace cartridge.
Solid or blinking red
See Service Indicator Codes.
T300 MODEL WITH PRO-PANEL CONTROLS
There are two types of user modes that will interface
with the operator home screen:
Operator Mode -
Capable of machine operation with
permissions and restrictions controlled by the
supervisor.
Supervisor Mode -
Capable of machine operation
with full use of all controls, along with configuring
permissions and restrictions for the operator mode.
A new machine from the factory will automatically start
up in the supervisor mode by default. To configure the
control panel with permissions and restrictions for the
operator mode, see SUPERVISOR CONTROLS
instructions at back of manual.
1. Turn the key to on ( I ) position. At start up, a
Tennant logo screen will first appear followed by the
operator home screen as shown below (Figure 44).
FIG. 44
Models equipped with the ec-H2O option, the ec-H2O
icon will appear at the center of the display. This
indicates the ec-H2O system is turned on and ready for
operation. The ec-H2O system will automatically turn
on at start up.
To turn off the ec-H2O system, press the ec-H2O on/off
switch located below the key switch. A slash mark over
the icon will indicate that the ec-H2O system is turned
off (Figure 45).