OPERATION
10
Tennant T300 (02- 2017)
INSTALLING BATTERIES
WARNING: Batteries emit hydrogen gas.
Explosion or fire can result. Keep sparks and open
flame away when charging.
FOR SAFETY: When servicing machine, wear
appropriate personal protection equipment as
needed. Avoid contact with battery acid.
BATTERY SPECIFICATIONS
Two 12 volt deep-cycle batteries.
Contact distributor or Tennant for battery
recommendations.
FOR SAFETY: Before leaving or servicing machine,
stop on level surface, turn off machine, remove key
and set parking brake if equipped.
1. Lift the recovery tank to access the battery
compartment (Figure 1).
FIG. 1
2. With adequate assistance, carefully install the
batteries into the battery compartment. Arrange the
batteries as shown (Figure 2).
FOR SAFETY: When servicing machine, use a hoist
or adequate assistance when lifting batteries.
3. Using the supplied battery post boots, connect the
cables to the battery posts as shown (Figure 2).
Connect the machine’s black (- ) battery cable last.
Use insulated tools when working near batteries.
M
achi
n
e
F
ront
BLACK
RED
FIG. 2
IMPORTANT: Make sure that the machine’s battery
charger is properly set before charging. See
BATTERY CHARGER SETTINGS.
For machines shipped without batteries and
equipped with an off-board battery charger, the
machine’s battery discharge indicator (BDI) is
factory programmed for GEL batteries as the
default.
If installing flooded (wet) lead/acid or AGM
batteries, the BDI MUST be reprogrammed to
prevent battery damage and/or short run- time. See
BATTERY CHARGER SETTINGS.
IRIS
®
Battery Charging Metrics Notification:
Machines equipped with capability to report battery
charging data via IRIS are supplied with a charger and
set of batteries from the factory. When a battery
reaches its end of life and must be replaced, Tennant
highly recommends that the same battery type be used
to continue to maximize the machines performance. In
the event a battery with a different amp hour (AH), type
(Flooded, AGM, Gel), or manufacturer is selected for
replacement please contact Tennant technical service
department for assistance in determining the feasibility
of the replacement batteries and if so, selecting the
correct charging profile. Availability of IRIS battery
metric reporting is not guaranteed with third party
supplied batteries.
BATTERY PACK LIFT- OUT TRAY (Option)
Models equipped with the optional battery lift-out tray
for quick or frequent battery pack exchange.
FOR SAFETY: Before leaving or servicing machine,
stop on level surface, turn off machine, remove key
and set parking brake if equipped.
WARNING: Batteries emit hydrogen gas.
Explosion or fire can result. Keep sparks and open
flame away when charging.
1. Disconnect the battery cable connection at
machine (Figure 3).
FIG. 3
FOR SAFETY: When servicing machine, wear
appropriate personal protection equipment as
needed. Avoid contact with battery acid.
2. Using an approved lift strap that supports the
weight of battery pack, connect the strap to the two
lift brackets as shown. Using a lift hoist rated to
handle the weight of the battery pack, carefully lift
the battery packs to and from machine. Keep one
hand on the battery lift-out tray when lifting for
stability (Figure 4).
Содержание Tennant GL20