OPERATION
Tennant T300 (02- 2017)
17
CONTROL PANEL OPERATION
T300 WITH MEMBRANE CONTROL PANEL
(Manual Down Pressure Model)
1. Turn the key to on ( I ) position to power up
machine.
Models equipped with the ec-H2O option - The
ecH2O system will automatically turn on at start up.
A blue ec-H2O icon will appear on the control panel
(Figure 32). This indicates that the ecH2O system
is turned on and ready for operation. To turn off the
ec-H2O system, press the ec-H2O switch located
below the key switch.
FIG. 32
2. Press the solution flow button to increase or
decrease the solution flow rate (Figure 33). The
solution flow indicator will display flow setting.
No LED = No flow, One LED = Low flow, two
LED’s = Medium flow, three LED’s = High flow.
FIG. 33
3. Models equipped with Severe Environment button
option - Press Severe Environment button one
time to dispense cleaning detergent for 30 seconds
(Figure 34). A green LED in the corner will blink
slowly when dispensing. During the last 5 seconds,
the LED will blink rapidly as an alert that the
dispensing is about to stop. For continuous
dispense, press and hold the button for 2 seconds
until LED turns solid green. Press button at
anytime to turn off.
The icon will blink blue when the severe
environment tank needs to be refilled.
NOTE: When the severe environment mode is
turned on, the solution flow setting will
automatically increase to the high setting. When
turned off, the setting will revert back to the original
setting. When operating the Severe Environment
mode for extended periods, if desired, the solution
flow rate can be decreased to a lower setting to
conserve solution and detergent usage.
FIG. 34
4. Press the Quiet-Mode button to reduce the vacuum
motor sound (Figure 35). A green LED in the
corner will turn on when mode is activated. Press
button to turn off.
NOTE: Water pickup will reduce slightly when
Quiet-Mode is activated.
FIG. 35
5. If a machine fault is detected during operation, the
service indicator will light up and begin flashing
(Figure 36). See SERVICE INDICATOR CODES.
If the ec-H2O system detects a fault during
operation, the ec-H2O icon will turn red or blink
red. See SERVICE INDICATOR CODES.
FIG. 36
ec-H2O INDICATOR
CONDITION
Solid blue
Normal operation
Blinking blue/red
Water conditioning cartridge
expired. Replace cartridge.
Solid or blinking red
See Service Indicator Codes.