Circuit Breaker
Reset Circuit Breaker
1 . Turn off power supply .
2 . Remove chlorinator from wall .
3 . Find circuit breaker on bottom near power cord .
4 . Push button in .
5 . Replace chlorinator on wall .
6 . Turn on power supply .
Replace Circuit Breaker
1 . Disconnect power supply .
2 . Remove chlorinator from wall .
3 . Remove 4 screws to remove cover .
4 . Disconnect ribbon wire connector from power PCB and set cover aside .
5 . Remove 2 push-on wire connectors from back of circuit breaker .
6 . Use pliers to squeeze base of circuit breaker and push through hole from the inside .
7 . Push new circuit breaker through hole from the outside till it snaps in place .
8 . Reconnect 2 push-on wires to back of circuit breaker .
9 . Reconnect ribbon wire connector to power PCB .
10 . Replace cover with 4 screws .
11 . Replace chlorinator on wall .
12 . Connect power supply .
Power Cord
Power Cord Replacement
1 . Disconnect power cord from power source .
2 . Remove chlorinator from wall .
3 . Remove 4 screws to remove cover .
4 . Disconnect ribbon wire connector from power PCB and set cover aside .
5 . Remove 3 Push-on wire connectors and unscrew ground wire from back .
6 . Use pliers to squeeze base of power cord holder and push through hole from the inside .
7 . Unclip power cord holder and transfer to new power cord .
8 . Push power cord holder with new power cord through hole from the outside till it snaps in place .
9 . Reconnect 3 push-on wire connectors and screw ground wire to back .
10 . Reconnect ribbon wire connector to power PCB .
11 . Replace cover with 4 screws .
12 . Replace chlorinator on wall .
13 . Connect power cord to power source .