14
LM3 Interface Instructions
Remove the LM3 power pack cover and connect the 4-conductor communication wire to the “eos com” terminal block on
the LM3 control PCB, mounted in the LM3 cover . The wiring configurations for various controllers are as shown below:
Polaris Eos
Jandy Aqualink RS
Pentair IntelliTouch
Note
: The wiring configurations are the same for both Jandy revision ‘K’ and revision ‘L’ controllers .
Note:
When connecting to the Jandy Aqualink RS controller with “Rev L” code the LM3 will
appear in the settings menu as an “AquaPure” chlorinator .
Securing the Communications Wiring
Fit the communication wire into the slot beside the output cable cord grip and secure the communication wire to the Cell
Output cable with cable ties .
Controller Interface
Because the LM3 chlorinator is capable of being connected to various controllers, it is necessary to select which
controller the LM3 is to be connected to . This is done as follows:
1 . Make a suitable cable connection .
2 . Turn the power to the LM3 ‘ON’ via the controller .
3 . Set the LM3 chlorine output to minimum (one Amber LED) via the OUTPUT
button on the front panel .
4 . Press the LM3 SERVICE button down for at least 20 seconds while observing
the green SUPER CHLORINATE LED . The LED will flash momentarily,
either
1, 2 or 3 times, then will go out for approximately 5 seconds .
5 . Continue to hold the SERVICE button down until the correct number
of
flashes
for the controller being used is observed .
Controller Selection
Controller:
# of Flashes:
Off Time:
POLARIS Eos
1
Approximately 5 seconds
PENTAIR IntelliTouch
1
Approximately 5 seconds
JANDY AquaLink RS (rev K)
2
Approximately 5 seconds
JANDY AquaLink RS (rev L)
3
Approximately 5 seconds
LM3 Display Panel
Hidden “Service” Button to the
top right of the “3”
LM3 Control PCB
Communication Terminal Block
Red
Green
Yel/White
Black
Black = (A)
Yel/White = Signal- (B)
Green = 0V
Red = V+
LM3 Control PCB
Communication Terminal Block
Red
Black
Green
Yel/White
Black = 0V
Yel/White = (A)
Green = Signal- (B)
Red = V+
Black = (A)
Yel/White = Signal- (B)
Green = 0V
Red = V+
LM3 Control PCB
Communication Terminal Block
Red
Green
Yel/White
Black