Triac Screws
The triac screws are the 3 screws at the base of the power PCB . It is imperative that these screws be tightened all the
way . The triac tabs are used to transfer heat from the power PCB to the back panel of the chlorinator .
If the triac screws are NOT tight, the power PCB will overheat and be damaged.
It is also imperative to have screw “C” insulated with the special washer and pad . This special washer and pad insulates
this triac tab while still allowing heat to transfer .
Triac Screws A B C
Note that screw “C” has an insulating pad
and washer that MUST be replaced when
the PC board is changed . These screws
must be tight in order to dissipate heat
from the board .