No Chlorine Reading
Are there any lights visible?
YES
NO
See pg. 6.
Will the output lights go all the way up?
YES
NO
Chlorinator is working properly. Recommend
to customer to have water sample
checked by dealer.
Add salt according to chart in
Owner’s Manual.
1. Is salt level 4000 ppm?
YES
NO
Have qualified electrician
wire to 220V.
2. Is unit wired 220V?
YES
NO
3. Does cell model / size
match power pack?
YES
NO
Replace with correct cell.
4. The cell is nearing the end of its life.
Replace cell.