Output Lights Will Not Go to 100%
Is salt level 4000 ppm or higher?
YES
NO
Add salt according to chart
in Owner’s Manual.
Check there is 220V incoming power.
YES
NO
Is water temperature below 65° F?
YES
NO
Add salt to compensate.
Cell may be nearing the end of its life. Check
cell age, run time & output setting.
Replace cell. (see Cell pg. 13)
For LM3 Models
Insure LM3 is properly interfaced. (see pg.
14) Check output setting & run time of LM3 at
controller remote pad. Increase as needed. If
output and run time were adequate, disconnect
communication wire at LM3 touchpad. LM3
now operates as a stand alone unit with
the output buttons on the LM3 power pack
controlling the operation.
If unit is less than 1 year old check
the following:
Check touch pad PCB.
(see Touch Pad PCB pg. 15)
Replace power PCB.
(see Power PCB pg. 17)
Have qualified electrician
rewire chlorinator to 220V.
Reconnect communication wire.
Interface LM3 with controller.
Adjust output and run time.