Installation manual
M
use GP
minipool
Страница 1: ...Installation manual Muse GP minipool...
Страница 2: ...ead this manual carefully before installing it The Treesse team is always available for any information or request for assistance that may be required during installation GRUPPO TRE S s p a Telephone...
Страница 3: ...___ 8 3 CONNECTIONS REQUIRED__________________________________________________________ 9 4 WATER SUPPLY_____________________________________________________________________ 12 CHARACTERISTICS OF THE W...
Страница 4: ...at do not follow the information provided in this manual can cause damages injuries or fatal accidents and null and void the warranty During the installation of the minipool do not place objects insid...
Страница 5: ...on port measuring at least 50 cm wide has been prepared on all sides of the minipool The connections to the electrical grid have been made in compliance with current regulations in force in the countr...
Страница 6: ...ys to reach the desired place of installation Movement must be carried out using personal protective equipment e g gloves safety shoes etc and taking all the necessary safety precau tions for those in...
Страница 7: ...into the prepared space If it was not possible to provide a technical inspec tion port on all sides of the minipool a pneu matic lift is available optional to be request ed from the Manufacturer in o...
Страница 8: ...r Before installation it is recommended to carefully read the safety warnings at the beginning of this manual and to always operate in perfect physical and mental condition The installer qualified and...
Страница 9: ...mbing connection to an exchanger optional if provided see following page The following pages will provide detailed explanations of how to perform these preparations Examples of outdoor indoor minipool...
Страница 10: ...1 BL2 HTR Cromo 230V EVc EVs EVclv J49 J48 230V heater exchanger control cable C switch recommended OUT outgoing cold water P circulator not supplied PR recirculation pump S exchanger not supplied The...
Страница 11: ...nical inspection port IN water inlet OUT water outlet 230V IN PR F C CP 230V circulator control cable OUT water outlet IN water inlet PR recirculation pump F filter C control unit Inlet connection 1 1...
Страница 12: ...ariations Water pH What is pH The pH is a chemical parameter that gives an idea of the acidity or basicity of the water It can assume values between 0 and 14 By definition water is considered neutral...
Страница 13: ...he instructions provided by the manufacturer of the cleaning product used Paper filters should be mounted when they are com pletely dry 5 2 1 4 3 6 emptying the minipool CLICK 1 2 4 3 Emptying takes p...
Страница 14: ...ty equal to 60A or in any case adequate for the absorption of the bathtub Controlled by a differential switch no larger than 30mA The control unit s power supply cable must be of the H05 type with thr...
Страница 15: ...e minipool for a distance of at least 60 cm and a height of 230 cm Make sure that The minipool is level and stable Electrical connections are made correctly in accordance with local and national codes...
Страница 16: ...the quality of the water supply This is very important for the well being of the users and for the long life of the minipool For more information see chapter Characteristics of the water supply on pag...
Страница 17: ...ntrol panel display lights up press the Jet key once to activate pump 1 at low speed and press it a second time to increase the speed If you have a second pump press the Jet2 key to activate it The pu...
Страница 18: ...ndicates that it is necessary to wait before knowing the water temperature in order for it to be detected correctly in fact the pump dedicated to water circulation must have been in operation for at l...
Страница 19: ...ption No water in the heater All minipool functions are disabled After solving the problem remove and restore the power to initialize the water heating procedure See the Water flow problems section Th...
Страница 20: ...description The sensor connected to the temperature survey or the circuit sensor do not work Solutions Contact Technical Service VARIOUS TYPES OF MESSAGES DISPLAY SCREEN DESCRIPTION OF SIGNALS AND PO...
Страница 21: ...Solutions Contact Technical Service Configuration error The minipool doesn t start Solutions Contact Technical Service GFCI fault The system is not connected to the GFCI M036 Problem description ONLY...
Страница 22: ...22 EN Muse GP minipool Mount the wood or laminate resin panels as shown in the figures below Decorative panels 2 3 1 1 3 2...
Страница 23: ...is especially useful if the minipool is installed outdoors In this case it might be useful to anchor it with lashing straps in order to prevent the wind from moving it or blowing it off Covering Maxim...
Страница 24: ...www gruppotreesse it GRUPPO TRE S s p a 01036 Nepi VT Italy S S Cassia km 36 400 Settevene industrial area tel 39 0761 527242 fax 39 0761 527223 info gruppotres it Muse GP installation Edition 10 2020...