minipool
Alarms
If any alarms appear during initial startup, read the instructions provided in the following table. If the solution is not
possible, immediately contact the manufacturer to request technical support. In the meantime, do not try to repair
or use the minipool but rather disconnect it from the electricity and water supplies.
gEnErAl
MESSAgES
DISPlAy
SCrEEn
DESCrIPTIon oF SIgnAlS AnD PoSSIBlE SoluTIonS
Initialization
(Priming mode)
M019
Problem description:
Every time the system is activated it automatically
enters initialization mode to allow the user to operate each pump sepa-
rately and to manually check that the air has been eliminated from the
circuit and the water is flowing, operations not possible during normal
operation. Initialization mode lasts 4 minutes but it is possible to exit
the function before by pressing any Temperature key.
Heating is not allowed during the initialization mode.
Note: If the pool has a recirculation pump, it turns on with “Jets 1”
during the initialization process and activates autonomously when the
process is finished.
Water
Temperature is
Unknown
(notification)
READY
RANGE
READY
RANGE
or
Problem description:
The message indicates that it is necessary to wait
before knowing the water temperature: in order for it to be detected
correctly, in fact, the pump dedicated to water circulation must have
been in operation for at least one minute.
Solutions:
wait a minute to view the water temperature.
Frost protection
(notification)
READY
RANGE FLTR1
Problem description:
The system has detected that conditions exist
for the water to freeze. Therefore, to avoid this, all the pumps are au-
tomatically activated and remain active for at least 4 minutes after the
freezing danger has passed.
Solutions:
The starting and stopping of the pumps is automatic but
further utilities (e.g. heater) can be switched on or off to better protect
against freezing.
Water too hot
(OHS) – M029
Problem description:
The sensors have detected a potential danger
due to the water temperature being too high, above 43.3°C (110°F).
The minipool functions are disabled.
Solutions:
When a temperature lower than 42.2°C (108°f) is restored,
the message disappears and normal operation resumes. Check for a
possible pump malfunction or high temperature.
Suction pump
block* M033
Problem description:
The error message “Safety trip” indicates that
the suction pump is blocked due to a suction problem or an obstruction.
(Note: not all minipools have this function).
Solutions:
Contact Technical Service
* this message can be deleted from the top of the panel by pressing any key.