background image

18

EN

M

use GP

 

minipool

Alarms

If any alarms appear during initial startup, read the instructions provided in the following table. If the solution is not 

possible, immediately contact the manufacturer to request technical support. In the meantime, do not try to repair 

or use the minipool but rather disconnect it from the electricity and water supplies.

gEnErAl 

MESSAgES

DISPlAy 

SCrEEn

DESCrIPTIon oF SIgnAlS AnD PoSSIBlE SoluTIonS

Initialization 
(Priming mode)
M019

Problem description:

 

Every time the system is activated it automatically 

enters initialization mode to allow the user to operate each pump sepa-

rately and to manually check that the air has been eliminated from the 

circuit and the water is flowing, operations not possible during normal 

operation. Initialization mode lasts 4 minutes but it is possible to exit 

the function before by pressing any Temperature key.

Heating is not allowed during the initialization mode.

Note: If the pool has a recirculation pump, it turns on with “Jets 1” 

during the initialization process and activates autonomously when the 

process is finished.

Water 
Temperature is 
Unknown
(notification)

READY

RANGE

READY

RANGE

or

Problem description: 

The message indicates that it is necessary to wait 

before knowing the water temperature: in order for it to be detected 

correctly, in fact, the pump dedicated to water circulation must have 

been in operation for at least one minute.

Solutions: 

wait a minute to view the water temperature.

Frost protection 
(notification)

READY

RANGE FLTR1

Problem description:

 The system has detected that conditions exist 

for the water to freeze. Therefore, to avoid this, all the pumps are au-

tomatically activated and remain active for at least 4 minutes after the 

freezing danger has passed. 

Solutions:

 

The starting and stopping of the pumps is automatic but 

further utilities (e.g. heater) can be switched on or off to better protect 

against freezing. 

Water too hot 
(OHS) – M029

Problem description:

 The sensors have detected a potential danger 

due to the water temperature being too high, above 43.3°C (110°F).

The minipool functions are disabled. 

Solutions:

 

When a temperature lower than 42.2°C (108°f) is restored, 

the message disappears and normal operation resumes. Check for a 

possible pump malfunction or high temperature.

Suction pump 
block* M033

Problem description:

 The error message “Safety trip” indicates that 

the suction pump is blocked due to a suction problem or an obstruction. 

(Note: not all minipools have this function).

Solutions:

 

Contact Technical Service

* this message can be deleted from the top of the panel by pressing any key.

Содержание Muse GP

Страница 1: ...Installation manual Muse GP minipool...

Страница 2: ...ead this manual carefully before installing it The Treesse team is always available for any information or request for assistance that may be required during installation GRUPPO TRE S s p a Telephone...

Страница 3: ...___ 8 3 CONNECTIONS REQUIRED__________________________________________________________ 9 4 WATER SUPPLY_____________________________________________________________________ 12 CHARACTERISTICS OF THE W...

Страница 4: ...at do not follow the information provided in this manual can cause damages injuries or fatal accidents and null and void the warranty During the installation of the minipool do not place objects insid...

Страница 5: ...on port measuring at least 50 cm wide has been prepared on all sides of the minipool The connections to the electrical grid have been made in compliance with current regulations in force in the countr...

Страница 6: ...ys to reach the desired place of installation Movement must be carried out using personal protective equipment e g gloves safety shoes etc and taking all the necessary safety precau tions for those in...

Страница 7: ...into the prepared space If it was not possible to provide a technical inspec tion port on all sides of the minipool a pneu matic lift is available optional to be request ed from the Manufacturer in o...

Страница 8: ...r Before installation it is recommended to carefully read the safety warnings at the beginning of this manual and to always operate in perfect physical and mental condition The installer qualified and...

Страница 9: ...mbing connection to an exchanger optional if provided see following page The following pages will provide detailed explanations of how to perform these preparations Examples of outdoor indoor minipool...

Страница 10: ...1 BL2 HTR Cromo 230V EVc EVs EVclv J49 J48 230V heater exchanger control cable C switch recommended OUT outgoing cold water P circulator not supplied PR recirculation pump S exchanger not supplied The...

Страница 11: ...nical inspection port IN water inlet OUT water outlet 230V IN PR F C CP 230V circulator control cable OUT water outlet IN water inlet PR recirculation pump F filter C control unit Inlet connection 1 1...

Страница 12: ...ariations Water pH What is pH The pH is a chemical parameter that gives an idea of the acidity or basicity of the water It can assume values between 0 and 14 By definition water is considered neutral...

Страница 13: ...he instructions provided by the manufacturer of the cleaning product used Paper filters should be mounted when they are com pletely dry 5 2 1 4 3 6 emptying the minipool CLICK 1 2 4 3 Emptying takes p...

Страница 14: ...ty equal to 60A or in any case adequate for the absorption of the bathtub Controlled by a differential switch no larger than 30mA The control unit s power supply cable must be of the H05 type with thr...

Страница 15: ...e minipool for a distance of at least 60 cm and a height of 230 cm Make sure that The minipool is level and stable Electrical connections are made correctly in accordance with local and national codes...

Страница 16: ...the quality of the water supply This is very important for the well being of the users and for the long life of the minipool For more information see chapter Characteristics of the water supply on pag...

Страница 17: ...ntrol panel display lights up press the Jet key once to activate pump 1 at low speed and press it a second time to increase the speed If you have a second pump press the Jet2 key to activate it The pu...

Страница 18: ...ndicates that it is necessary to wait before knowing the water temperature in order for it to be detected correctly in fact the pump dedicated to water circulation must have been in operation for at l...

Страница 19: ...ption No water in the heater All minipool functions are disabled After solving the problem remove and restore the power to initialize the water heating procedure See the Water flow problems section Th...

Страница 20: ...description The sensor connected to the temperature survey or the circuit sensor do not work Solutions Contact Technical Service VARIOUS TYPES OF MESSAGES DISPLAY SCREEN DESCRIPTION OF SIGNALS AND PO...

Страница 21: ...Solutions Contact Technical Service Configuration error The minipool doesn t start Solutions Contact Technical Service GFCI fault The system is not connected to the GFCI M036 Problem description ONLY...

Страница 22: ...22 EN Muse GP minipool Mount the wood or laminate resin panels as shown in the figures below Decorative panels 2 3 1 1 3 2...

Страница 23: ...is especially useful if the minipool is installed outdoors In this case it might be useful to anchor it with lashing straps in order to prevent the wind from moving it or blowing it off Covering Maxim...

Страница 24: ...www gruppotreesse it GRUPPO TRE S s p a 01036 Nepi VT Italy S S Cassia km 36 400 Settevene industrial area tel 39 0761 527242 fax 39 0761 527223 info gruppotres it Muse GP installation Edition 10 2020...

Отзывы: