Bring the buffer tubes to the opposite side of the MPT bulkhead that the
original buffer tube is secured to. You will secure the buffer tubes down
at this location. Mark the length to reach the tie-down location on each
buffer tube, and open the tubes 1/2 inch after that to expose the 900
micron fibers.
Secure all buffer tubes in place with velcro, or grommet tape and zip
ties.
5.
6.
Store the 900 micron fibers to be spliced in the upper splice tray. Wrap 1
1/2 laps of fiber and bring them to the center of the splice chip, then trim
them to length. Do the same with the 250 micron fibers to be spliced.
Perform your splices and place the splice sleeves in the splice chip in
the center of the splice tray. Store the slack inside the upper portion of
the splice tray and reinstall the splice tray cover.
7.
8.