Manual 021023 REV A - Jan 2020
• Use the hole on end of pad to
clean one alignment pin, then
press the end of the swab
into the other pin to clean.
•
Check your work with a fiber
scope. This can take several
attempts to get the endface
clean.
Female Connector (without pins)
•
Cleaned like a single fiber connector, using a cleaning platform. The
receptacles will be cleaned as long as you are using a combination clean-
ing process as recommended.
• Again, using a platen, moisten the platen with cleaning solvent on one
end to accommodate 3 swipes of the MPO female endface.
• Holding the connector (If APC, slightly at an angle to accommodate for 8°
angle) swiping with medium pressure, from the wet area into the dry area
3 times, without wiping over previous area.
• Inspect, and if clean, make the connection. If NOT, repeat above steps
until clean or if determined that the end face is damaged (based on stan-
dards of 5 cleanings per connection), replace.