Direct: 763.476.6866 • National: 800.422.2537 • www.SeeClearfield.com • [email protected]
22
YOURx Multi-Purpose Terminal
Installation Manual
_________________________________________________________
Manual 021023 REV A - Jan 2020
Ground per your local practice.
8.
Reinsert the ground stud and screw it through the base of the MPT
until about 1” of the stud is on the inside of the terminal. Remove
the two nuts from the back of the stud used to screw it in to place.
Install the nuts and washers on the ground stud on the inside of the
terminal.
After you have installed the cable gasket plate (see relevant sec-
tion), use the remaining nuts and washers to secure the grounding
stud from the other side.
10.
9.
11.