User Guide
|
Eclipse HX-PiCo
Page 40
#2/5 Normally closed
#2/5 Normally open
#3/6 COM
Table 9: Key to Figure 13: RLY-6 DB-9M connector pinout
RLY-6 interface module in an IMF-102 interface frame
Connecting to a RLY-6 interface module in an IMF-102 interface frame is the same
as connecting to a RLY-6 interface module in an IMF-3 interface frame.
The only difference is that an IMF-102 interface frame houses only two interfaces,
which are mounted horizontally rather than vertically in the frame.
Note:
For more detailed information, see the individual documentation for these interfaces
and frames, and the Eclipse HX Matrix Frame Installation Guide.
EHX configuration
Use the EHX configuration software to associate a relay to a label. For more
information, see your EHX documentation (including EHX Help).
Connecting to a GPI-6 interface module
The GPI-6 input interface module connects up to six programmable inputs to the
matrix so that each input can control a predefined matrix function. Multiple GPI-6
interface modules can be daisy-chained to provide connection of up to 60 inputs to
the matrix. RLY-6 and GPI-6 interface modules can be mixed together up to the
total limit of 60 items.
Five RLY-6 and five GPI-6 modules provide 30 relays and 30 inputs for a total of 60
inputs and outputs.
Note:
If both GPI-6 and RLY-6 interface modules are use, you must place the GPI-6
interface modules first in the daisy chain.
GPI-6 interface module in an IMF-3 interface frame
To connect the GPI-6 interface module to the matrix:
1)
Connect the RJ-45 cable (eight wires with no reversal) to the GPI/RLY
INTERFACE connector on the back of the matrix.
2)
Connect the other end of the RJ-45 cable into the top RJ-45 (CH. A
MATRIX) connector for the GPI-6.
To connect an additional GPI-6 interface module:
1)
Connect one end of a short RJ-45 cable into the lower RJ-45 (CH. B
MATRIX) for the first GPI-6.