background image

 

 

 

 

 

 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

Eclipse

®

  

HX-PiCo  

 

User Guide for the 

HX-PiCo matrix 

 

 
 
 

 

Part Number: 399G145 Rev B 
Date: 03/June/15 

 

 

 

 

User 

Guide

 

Содержание Eclipse HX-PiCo

Страница 1: ...Eclipse HX PiCo User Guide for the HX PiCo matrix Part Number 399G145 Rev B Date 03 June 15 User Guide...

Страница 2: ...engineering No part of this document may be reproduced in any form by any means without prior written authorization of Clear Com an HME Company Clear Com Offices are located in California USA Cambrid...

Страница 3: ...o front panel controls and lights 15 4 Connecting to external devices 19 4 1 Intelligent linking between Eclipse HX matrix frames matrices 19 Intelligent linking with PiCo Link 19 Linking to user pane...

Страница 4: ...io routes 51 6 5 Selecting and activating a configuration map 52 6 6 Setting the IP address for the Eclipse HX PiCo 53 6 7 Accessing system information 55 6 8 Accessing system status 56 6 9 Selecting...

Страница 5: ...User Guide Eclipse HX PiCo Page 5 8 8 Notice about Specifications 68 8 9 Menu Map for the Eclipse HX PiCo 69 9 Glossary 70 10 Compliance 75...

Страница 6: ...r safety If the provided plug does not fit into your outlet consult an electrician for replacement of the obsolete outlet 10 Protect the power cord from being walked on or pinched particularly at plug...

Страница 7: ...e 7 fallen into the apparatus the apparatus has been exposed to rain or moisture does not operate normally or has been dropped 15 Warning To reduce the risk of fire or electric shock do not expose thi...

Страница 8: ...er supply to the mains supply must conform to the following The mains power cord shall have an IEC C13 connector at one end and a mains power plug at the other end An IEC C13 plug has three pins the c...

Страница 9: ...he guide Provides an overview of the Eclipse HX PiCo including intelligent linking with other Eclipse HX matrices Eclipse HX Omega Eclipse HX Median and other Eclipse HX PiCo matrix frames Describes h...

Страница 10: ...the Eclipse HX PiCo This chapter provides brief guidance on maintaining the Eclipse HX PiCo 8 Specifications Technical specifications for the Eclipse HX PiCo 0 Error Not a valid result for table Menu...

Страница 11: ...cards 1 2 CPU cards and 15 16 interface cards in a six rack unit 6RU frame For more information see the Eclipse HX Omega User Guide Eclipse HX Median The Eclipse HX Median matrix frame has slots for...

Страница 12: ...stry Association equipment rack No parts of the unit are removable without the matrix frame being taken out of service The front panel of the Eclipse HX PiCo provides controls pushbuttons indicator li...

Страница 13: ...nterparts the Eclipse HX Omega and the Eclipse HX Median matrices Applications of the Eclipse HX PiCo The Eclipse PiCo provides high quality full duplex communications for applications requiring a mod...

Страница 14: ...t In addition the two supplies have separate IEC connectors to AC mains and are designed for completely automatic and transparent changeover between supplies in the event of a power outage in one of t...

Страница 15: ...User Guide Eclipse HX PiCo Page 15 Eclipse HX PiCo front panel controls and lights Figure 2 Front panel controls and lights 1 2 3 4 5 6 8 9 7...

Страница 16: ...rations in its operational memory Any one of the four configurations can be activated using the CONFIG button on the matrix front panel When one of the four configurations is active its front panel li...

Страница 17: ...larm light to illuminate If any of the voltages produced by the first power supply unit fall below normal levels If any of the voltages produced by the second power supply unit fall below normal level...

Страница 18: ...ontrol a variety of actions can be performed directly on the Eclipse HX PiCo matrix without recourse to the EHX configuration software hosted on an external PC For more information about using the Ecl...

Страница 19: ...able open trunks Note You cannot connect two Eclipse HX PiCo matrix frames with a trunk line if they have already been connected using a PiCo Link connection see section below Trunk lines can only be...

Страница 20: ...atrix port to other types of signals that communicate with devices such as telephones camera intercoms two way radios and so on In this way non four wire devices can communicate with the central matri...

Страница 21: ...wnload the configurations to the Eclipse HX PiCo as required EHX 7 6 runs on the following versions of Windows Microsoft Windows 7 32 bit and 64 bit Microsoft Windows 8 1 32 bit and 64 bit Microsoft W...

Страница 22: ...t every item on the list has been received Save all packing materials in the event any items need to be returned 16 Unpacking the System The system comprises the Eclipse HX PiCo matrix hardware and th...

Страница 23: ...nit being switched off for a period of time The Eclipse HX PiCo battery is normally a 1 2AA 3V VARTA 6127 201 301 and is fitted on shipment The battery has a capacity of 970mAh and a life of approxima...

Страница 24: ...User Guide Eclipse HX PiCo Page 24 Rear panel connectors Figure 3 Rear panel connectors...

Страница 25: ...o Eclipse HX PiCo matrix frames together forming a non blocking system of 72 ports 7 LAN connector RJ 45 For Ethernet connections Table 4 Key to Figure 4 Rear panel connectors 5 2 Connecting user pane...

Страница 26: ...the matrix on these ports A shielded cable should be used 5 3 Wiring schemes The Eclipse HX PiCo uses A 4 pair analog wiring scheme between the matrix and user panels V Series and I Series user panels...

Страница 27: ...s a 2 pair analog wiring scheme between the matrix and four wire equipment Note The wiring scheme shown in Figure 5 below is for four wire equipment with an RJ 45 connector For four wire equipment wit...

Страница 28: ...not used Pair 2 Transmits digital data from the four wire device back to the matrix Pair 3 Transmits audio from the four wire device to the matrix Pair 4 Pair 4 is not used Table 6 2 Pair analog Figu...

Страница 29: ...cket labeled GP OUT allows the Eclipse HX PiCo matrix to be connected to eight general purpose outputs GPOs General purpose outputs are single pole double throw relays with contact ratings of 30 VDC v...

Страница 30: ...neral purpose output is inactive the associated common pin on the GP OUT connector will be shorted to the relevant normally closed pin When a general purpose output becomes active the short between th...

Страница 31: ...ctor 10 1 2 3 4 5 6 7 8 9 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 Normally open Common RELAY6 Normally closed Normally open Common RELAY5 Normally closed Normally closed Normally open Common RELA...

Страница 32: ...tor DB 25M Connections using general purpose inputs GPI s The DB 25 connector labeled GP IN connects the matrix to eight local general purpose inputs GPIs An external logic device such as an external...

Страница 33: ...it the current through the opto isolator It is therefore possible to connect the input pins directly to a ground pin to cause an active input Note The voltage level at the external input pin should no...

Страница 34: ...this mode a DC voltage of between 7 24 V is required at the EXTVIN pin with relation to the EXTVIN pin To cause an input to detect an active signal current must be sent from the relevant input pin The...

Страница 35: ...nput 1 Pin 2 Logic input 2 Pin 3 Logic input 3 Pin 4 Logic input 4 Pin 5 N A Pin 6 N A Pin 7 N A DB 25F connector 10 1 2 3 4 5 6 7 8 9 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 Logic input 1 Logic...

Страница 36: ...frame Up to ten GPI 6 or RLY 6 modules can be operated at one time from the matrix by daisy chaining the cards together Each card has an IN and an OUT connector for this purpose The RLY 6 and GPI 6 i...

Страница 37: ...the lower RJ 45 CH B MATRIX for the first RLY 6 2 Connect the other end of the short RJ 45 cable into the top RJ 45 CH A MATRIX connector for the additional RLY 6 Additional RLY 6 interfaces are adde...

Страница 38: ...connect external devices to the RLY 6 interface module in an IMF 3 interface module frame use the two DB 9M connectors on the rear cable assembly panel for the interface If a DB 9F is plugged into the...

Страница 39: ...or example 1 4 COM refers to the wiper of relay 1 if it is connected to CH A and the wiper of relay 4 if it is connected to CH B Figure 12 RLY 6 DB 9M connector pinout Key to Figure 13 RLY 6 DB 9M con...

Страница 40: ...The GPI 6 input interface module connects up to six programmable inputs to the matrix so that each input can control a predefined matrix function Multiple GPI 6 interface modules can be daisy chained...

Страница 41: ...e the GPI 6 interface modules first in the daisy chain see Figure 11 RLY 6 GPI 6Daisy Chain Connection The maximum combined length of all the RJ 45 cables should not exceed 20 ft 6 m Connecting extern...

Страница 42: ...e 13 GPI 6 DB 9M connector pinout Connector Description 1 4 Input A 2 5 Input A 3 6 Input A Ground Ground 1 4 Input B 2 5 Input B 3 6 Input B Power source Table 10 Key to Figure 13 GPI 6 DB 9M connect...

Страница 43: ...e 43 Figure 14 shows how to connect switches or contacts using the power source provided by the GPI 6 module or powering switches from external sources Each input can be wired to be isolated from each...

Страница 44: ...ink You can create one non blocking 64 port Eclipse HX system by connecting two Eclipse HX PiCo matrix frames matrices together using the PiCo Link RJ 45 connectors on the matrices To make this connec...

Страница 45: ...ter is normally connected to the matrix using the LAN connector a standard RJ 45 Ethernet connector on the rear of the HX PiCo Ethernet connection allows single or multiple PCs to control configure mo...

Страница 46: ...3 to jack plug ring are followed Pin 5 DB 9F goes through to the jack plug screen The cable will then be ready to use Figure 16 Pin connections for PC DB 9F to Eclipse HX PiCo 3 5mm jack PC Connection...

Страница 47: ...n To view the main menu press the Setup Enter rotary control to the right of the display screen Scroll to a menu item by turning the rotary control When the desired menu item is highlighted on screen...

Страница 48: ...equires the FOR 22 interface module 4 four wire audio P panel N four wire network trunk T telephone requires the TEL 14 interface module Table 13 Port status codes Type of connection Note Ports 33 thr...

Страница 49: ...audio levels a From the Input Level menu scroll to the Port number Press and release the Setup Enter rotary control b Rotate the setup enter rotary control clockwise to display the available port digi...

Страница 50: ...tary control to select it Using the rotary control scroll to Level Press and release the rotary control to select Level Note Rotate the rotary control clockwise or counter clockwise to display availab...

Страница 51: ...d on the screen that port s label as set in EHX is automatically displayed 2 Scroll to the Source number Press and release the setup enter rotary control 3 Rotate the setup enter rotary control clockw...

Страница 52: ...screen is displayed 2 To confirm the route scroll to and select Yes To back out from the changes select either No or Exit 6 5 Selecting and activating a configuration map Each Eclipse HX PiCo matrix c...

Страница 53: ...ets the system to the currently selected configuration while restoring active calls and activating any changes made from the Eclipse HX PiCo s front panel since the last reset Clear Xpoints Resets the...

Страница 54: ...enu is displayed 2 From the System menu select IP address The IP Address screen is displayed Note If the matrix software has been reloaded or reset or a DHCP server was not found the local link defaul...

Страница 55: ...iguration while clearing active calls and clearing any changes made from the Eclipse HX PiCo s front panel since the last reset Table 16 Reset options 10 The IP address for the HX PiCo is now assigned...

Страница 56: ...status Information about the system s status high speed link connection and local area network connection can be accessed directly from the HX PiCo s front panel To access system status information 1...

Страница 57: ...us of a local area network if one is connected When an X is displayed in the UP checkbox the LAN is connected When an X is displayed in the Activity checkbox the LAN is receiving information Table 17...

Страница 58: ...ctive calls and activating any changes made from the Eclipse HX PiCo s front panel since the last reset Another type of reset restores the currently selected configuration map while clearing active ca...

Страница 59: ...or the logic output of some other device to the GP IN connector on the rear panel of the Eclipse HX PiCo When the external logic device is activated it sends a control signal into the matrix to perfor...

Страница 60: ...attention of a panel operator working in a high noise environment such as a control booth it can be programmed as a relay to switch on a light at the panel each time an incoming call is received to e...

Страница 61: ...lect its associated checkbox To toggle a GPO off clear its associated checkbox 3 A screen appears asking for confirmation of the selection Select Yes to confirm Select No or Exit to cancel the changes...

Страница 62: ...ower supplies The Eclipse HX PiCo matrix includes two internal power supply units One power supply unit can power an entire matrix the second unit provides a backup in case of an equipment failure In...

Страница 63: ...12 inches Weight 5 kg max Power consumption 60 W Max per inlet Number of panel compatible ports 32 Number of analog audio ports 4 Number of expansion modules 1 Number of power supply units 2 Max numb...

Страница 64: ...ominal Level 0 dBu Matrix headroom 18 dBu Distortion 0 05 0 dBu 300 Hz to 10 kHz 0 1 0 dBu 100 Hz to 20 kHz Off Noise 98 dBu relative to 18 dBu 20 Hz 22kHz On Noise 83 dB relative to 18 dBu 20 Hz 22kH...

Страница 65: ...6 RLY 6 RJ 45 connector on rear panel Network 10 100 Base T Ethernet Max distance 100m RJ 45 connector on rear panel Serial PC RS 232 3 5mm connector on front panel Baud rate 57600 Max distance 10 me...

Страница 66: ...olution SVGA User entry Keyboard Mouse Ports 2 serial ports and or network IEEE 802 3 Ethernet card Network IEEE 802 3 Ethernet card Operating systems EHX 7 6 runs on the following versions of Windows...

Страница 67: ...it Free space 1GB minimum 32 bit 2GB minimum 64 bit Display resolution 1600 x 1200 Operating systems EHX 7 6 runs on the following versions of Windows Microsoft Windows 7 32 bit and 64 bit Microsoft W...

Страница 68: ...ended PC requirements 8 8 Notice about Specifications While Clear Com makes every attempt to maintain the accuracy of the information contained in its product manuals that information is subject to ch...

Страница 69: ...X PiCo Page 69 8 9 Menu Map for the Eclipse HX PiCo Note The following menu map does not include screens for confirmation and reboot which are displayed automatically after some screens Figure 29 Ecli...

Страница 70: ...located in the etched surface of the midplane Call signal A call signal is an electronic signal sent from one panel or interface to another A call signal can be audible and or visual Typically a call...

Страница 71: ...duplex meaning that they can both talk and listen simultaneously The Eclipse HX matrices provide full duplex audio EHX EHX is the Eclipse HX configuration software EHX guides the operation of the mat...

Страница 72: ...o some other form of communication such as 2 wire partyline telephone etc The interface module is connected to a central matrix port The external non four wire device is then connected to the interfac...

Страница 73: ...rotocol defines the data format and electrical characteristics of an interface carrying multiple channels of digital audio Multiplexing The process by which two or more signals are transmitted over a...

Страница 74: ...U is 1 75 inches 44 45 mm of vertical mounting space 2 RU is 3 5 inches 88 9 mm 3 RU is 5 25 inches 133 35mm and so on Remote panel Any intelligent intercom device connected to the back panel ports of...

Страница 75: ...t may cause undesired operation Note This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to part 15 of the FCC Rules These limits are designed to p...

Страница 76: ...num rique de la classe B est conforme la norme NMB 003 du Canada Korean notice This notice applies to the following products Eclipse HX PiCo Eclipse PiCo V12RDX V12RDX4 V12LDX4Y IP V12PDX4Y IP V12RDX...

Отзывы: