4.6. Setup Troubleshooting
This appendix deals with connection problems that might occur when connecting a
management computer to a Clavister Next Generation Firewall.
If the management interface does not respond after the Clavister Next Generation Firewall has
powered up and cOS Core has started, there are a number of simple steps to troubleshoot basic
connection problems:
1. Check that the correct interface is being used.
The most obvious problem is that the wrong Clavister Next Generation Firewall interface has
been used for the initial connection. Only the first interface found by cOS Core is activated for the
initial connection after cOS Core starts for the first time.
2. Check that interface characteristics match.
If a Clavister Next Generation Firewall's interface characteristics are configured manually then the
interface on a switch to which it is connected should be configured with the same characteristics.
For instance, the link speeds and half/full duplex settings must match. If they do not,
communication will fail. This problem will not occur if the interfaces are set for automatic
configuration on both sides and automatic is always the Clavister factory default setting.
3. Check that the management computer IP is configured correctly.
The second most obvious problem is if the IP address of the management computer is not
configured correctly.
4. Is the management interface properly connected?
Check the link indicator lights on the management interface. If they are dark then there may be a
cable problem.
5. Using the ifstat CLI command.
To investigate a connection problem further, connect the a console to the local console port on
the Clavister Next Generation Firewall. Once cOS Core has started, it should respond with the a
standard CLI prompt when the enter key is pressed. Now enter the following command once for
each interface:
Device:/> ifstat <if-name>
Where
<if-name>
is the name of the management interface. This will display a number of
counters for that interface. The
ifstat
command on its own can list the names of all the interfaces.
If the
Input
counters in the hardware section of the output are not increasing then the error is
likely to be in the cabling. However, it may simply be that the packets are not getting to the
Clavister Next Generation Firewall in the first place. This can be confirmed with a packet sniffer if
it is available.
If the
Input
counters are increasing, the management interface may not be attached to the
correct physical network. There may also be a problem with the routing information in any
connected hosts or routers.
6. Using the arpsnoop CLI command.
A diagnostic test to try is using the console command:
Device:/> arpsnoop all
This will display console messages that show all the
ARP
packets being received on the different