AXIOMTEK NA-401 Скачать руководство пользователя страница 1

 

 

NA-401 

  Hardware Installation Guide 

For service person only 

Содержание NA-401

Страница 1: ...NA 401 Hardware Installation Guide For service person only...

Страница 2: ...AXIOMTEK makes no commitment to update or to keep current the information contained in this manual AXIOMTEK reserves the right to make improvements to this document and or product at any time and with...

Страница 3: ...However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined b...

Страница 4: ...properly grounded 3 Do not open the system s top cover If opening the cover for maintenance is a must only a trained technician is allowed to do so Integrated circuits on computer boards are sensitiv...

Страница 5: ...M 17 2 2 4 Installing a DMA 66 100 hard drive 18 2 2 5 Install a Riser Card 19 2 2 6 Connector and Jumper 23 2 2 7 Install Display Interface 23 2 2 8 Install Serial Port 23 2 2 9 Installing Keyboard P...

Страница 6: ...vi 3 13 Quit Without Saving 60 Appendix A Warning 62...

Страница 7: ...s a reliable and affordable 1U height unit that requires only power and network connections for setup There can be deployed up to four LAN ports combinations for customer selection in the maximum for...

Страница 8: ...ons are for NA 401 z Support BIOS redirected to COM port feature z Support RS 232 and two USB z PCI 32 bit 33MHz expansion slot and one Mini PCI slot for another network security encryption board z LC...

Страница 9: ...R266 DDR333 memory DIMM can be up to 4GB in the maximum z IDE Interface Support one ATA 66 100 133 EIDE channels Support four S ATA 1 0 channels z Serial Port One UART z Ethernet Totally has four LAN...

Страница 10: ...NA 401 Hardware Installation Guide Introduction 4 Air temperature 0 C 40 C Humidity 10 95 z Storage environment Air temperature 20 C 70 C Humidity 10 95...

Страница 11: ...NA 401 Hardware Installation Guide Introduction 5 1 4 Dimensions Unit mm...

Страница 12: ...ghts when the NA 401 is powered up and performing diagnostic tests to check for proper operation USB port For specialize functions was defined by solution provider LAN Link Lights up with a twisted pa...

Страница 13: ...Guide Introduction 7 1 6 Rear Panel Outlets Located at the rear panel of the NA 401 server are the I O outlets You will also find the main power switch and cooling fans Internal FANs 100 240VAC 50 60...

Страница 14: ...ive activity II Link Active LED Single color for LAN port 1 port 2 port 3 and port 4 1 The yellow LED is on when there is an active connection on the LAN port 2 The LED flashes when there is transmit...

Страница 15: ...Guide Introduction 9 3 The LED is dark if the Link Active LED is light or flash in the same time it s on 10Mbps transfer rate 4 The LED is dark if the Link Active LED is dark also There is no any net...

Страница 16: ...NA 401 Hardware Installation Guide Introduction 10 This page does not contain any information...

Страница 17: ...ing this installation guide Mounting screws for disk drive and screws used in this appliance for spare Quick installation guide Hardware Installation Guide NA 401 cable kits 1 x 44 pin IDE 1 x console...

Страница 18: ...appliance This section provides the information about the initial installation to setup the NA 401 2 2 1 Removing and Replacing the Top Cover To gain access into the internal components of the NA 401...

Страница 19: ...ocessor in the 775 land package refers to Pentium 4 processors in the 775 land Flip Chip Land Grid Array FC LGA4 package with an Integrated Heat Spreader IHS that aids in heat dissipation to a properl...

Страница 20: ...1 Hardware Installation Guide Installation Procedures 14 Figure 2 5 Opening the Socket Figure 2 6 Don t Touch Processor Contacts Figure 2 7 Locate Connection 1 indicator and the two orientation key no...

Страница 21: ...Hardware Installation Guide Installation Procedures 15 Figure 2 8 Grasp the processor with thumb and index finger Figure 2 9 Carefully place the package into the socket body using a purely vertical m...

Страница 22: ...ose the socket by 1 Close the Load Plate 2 While pressing down lightly on Load Plate engage the Load Lever 3 Secure Load Lever with Load Plate tab under retention tab of Load Lever PS The above mentio...

Страница 23: ...t sink Figure 2 11 Then to use the FAN dock to cover the heat sink with CPU Make it to be better efficiency from thermal point of view 2 2 3 Installing a memory module DIMM The main board can supports...

Страница 24: ...tch DIMM timings A CL 2 0 DIMM can be paired with a CL 2 5 DIMM as long as the geometry matches Attention X When you handle electrostatic discharge sensitive ESDs take precautions to avoid damage from...

Страница 25: ...site of the system placement Customer can fix it in the base of chassis by other screws 2 2 5 Install Riser Card Figure 2 13 The third party expansion card can be in the front of the device It s easil...

Страница 26: ...2 2 6 Connectors Jumpers The connectors allow the CPU card to connect with other parts of the system Some problems encountered by your system may be a result from loose or improper connections Ensure...

Страница 27: ...U FAN Connector CN40 CRT Connector CN8 System FAN1 Connector CN39 Keyboard Mouse Connector CN7 System FAN2 Connector CN38 External Mouse Connector CN10 System FAN3 Connector CN12 External Keyboard Con...

Страница 28: ...ink ACT LED JP1 Jumper Default Setting Jumper Setting JP18 CF Card Voltage Setting 3 3V Short 2 3 for 3 3V Short 2 3 for 5V JP17 CF Card Master Slave Setting Master Short 1 2 for Master Open 1 2 for S...

Страница 29: ...pin header CN29 These interfaces could be for LCM command transaction bus or another specifies features applications by customer 2 2 8 1 Serial Ports IRQ Selection RS 232 422 485 PIN Assignment COM1...

Страница 30: ...N9 CN10 Clock Data No Connection GND Power 1 2 5 4 3 2 2 10 Installing USB Connector Optional The Universal Serial Bus USB connector CN6 on the main board is for installation of peripherals supporting...

Страница 31: ...is should be PIN To PIN assignment The LCD is 16 by 2 it show 16 words in each row And can show totally 32 words with two rows 2 Data transfer format A command 0D hex PC AX89063 It moves the cursor t...

Страница 32: ...to 16 words and 41 to 56 words If would like to show the words with two rows of LCM the PC need to send the 80 bytes totally The each character will be fill in into the RAM of LCM which it was initia...

Страница 33: ...is ASCII code for D c ESC when it was press then release the LCM will send 4Chex to PC it is ASCII code for L d Enter when it was press then release the LCM will send 52hex to PC it is ASCII code for...

Страница 34: ...NA 401 Hardware Installation Guide Installation Procedures 28...

Страница 35: ...ts It also adds virus and password protection as well as special support for detailed fine tuning of the chipset controlling the entire system 3 2 BIOS Setup The Award BIOS provides a Setup utility pr...

Страница 36: ...e arrow keys to highlight items Enter to select the PgUp and PgDn keys to change entries F1 for help and Esc to quit When you enter the Setup utility the Main Menu screen will appear on the screen The...

Страница 37: ...he chipset defaults These defaults have been carefully chosen by both Award and your system manufacturer to provide the absolute maximum performance and reliability 3 3 Standard CMOS Setup Standard CM...

Страница 38: ...ch item field you can press the F1 key It will display the relevant information to help you The memory display at the lower right hand side of the menu is read only It will adjust automatically accord...

Страница 39: ...The categories identify the types of one channel that have been installed in the computer There are 45 predefined types and 2 user definable types are for Enhanced IDE BIOS Type 1 to Type 45 is predef...

Страница 40: ...access mode If there is no hard disk drive installed select NONE and press Enter Halt On This field determines whether the system will halt if an error is detected during power up No errors The syste...

Страница 41: ...dware Installation Guide Award BIOS Utility 35 3 4 Advanced BIOS Features This section allows you to configure and improve your system and allows you to set up some system features according to your p...

Страница 42: ...g your system off the control circuit will modulate frequency to maintain an acceptable temperature in the event of unexpected thermal spikes Thermal Management Thermal Monitor 2 make the function ena...

Страница 43: ...halt the system and display a warning message If this occurs you can either allow the operation to continue or run an anti virus program to locate and remove the problem NOTE Many disk diagnostic pro...

Страница 44: ...t setting is enabled Swap Floppy Drive The customer doesn t need to open chassis to change FDD A and FDD B The default setting is disabled Boot up NumLock Status This option enables and disables the n...

Страница 45: ...0 38400 57600 and 115200 Agent Wait Time min As part of the Boot Agent s Configuration Setup Program two of the options Show Setup Prompt and Setup Wait Time allow the boot process to proceed after PO...

Страница 46: ...will confirm the user password while it is in boot up situation If the setting is setup that only confirm the user password while enter into the BIOS setting The default is Setup 3 5 Advanced Chipset...

Страница 47: ...be available on the falling edge of the second clock following READ The default is Auto By BSD DRAM RAS to CAS Delay It is known as tRCD It is the delay in clock cycles from when the ACTIVE command i...

Страница 48: ...t of OS doesn t use the segment of memory in progressing The factory default should be disabled The choice Enabled Disabled PCI Express Root Port Function When a PCI E interrupt is received directly b...

Страница 49: ...NA 401 Hardware Installation Guide Award BIOS Utility 43 3 6 Integrated Peripherals This option sets your hard disk configuration mode and port...

Страница 50: ...NA 401 Hardware Installation Guide Award BIOS Utility 44...

Страница 51: ...econdary PCI IDE The integrated peripheral controller contains an IDE interface with support for two IDE channels Select Enabled to activate each channel separately The choice Enabled Disabled On Chip...

Страница 52: ...to SATA port 0 This mode it s support by Windows XP or later OS on it SATA2 master SATA controller set to SATA port 1 This mode it s support by Windows XP or later OS on it Serial ATA Port1 Mode USB...

Страница 53: ...Onboard Serial Port 1 Port 2 Select an address and corresponding interrupt for the first and second serial ports The choice 3F8 IRQ4 2E8 IRQ3 3E8 IRQ4 2F8 IRQ3 Disabled Auto Watch Dog Timer Sec The fe...

Страница 54: ...01 Hardware Installation Guide Award BIOS Utility 48 ACPI Function This item allows you to enable disable the Advanced Configuration and Power Management ACPI The choice Enabled Disabled Power Managem...

Страница 55: ...Suspend Mode When enabled and after the set time of system inactivity all devices except the CPU will be shut off The choice Enabled Disabled Power on by Ring Boot up through modem PCI Express PME If...

Страница 56: ...keyboard boot up if the power supply is using ATX 2 0 standard Hot Key Power On To use the hot key if the power supply is using ATX 2 0 standard PWRON after PWR Fail If the power supply failed that c...

Страница 57: ...e system reconfiguration has caused such a serious conflict that the operating system can not boot The options available are Enabled and Disabled Resource controlled by The Award Plug and Play BIOS ha...

Страница 58: ...rd BIOS Utility 52 IRQ Resources When resources are controlled manually assign each system interrupt a type depending on the type of device using the interrupt PCI VGA Palette Snoop Leave this field a...

Страница 59: ...alue Current System Temp Show you the current system temperature Current CPU1 Temperature Show you the current CPU1 temperature Current FAN1 FAN2 FAN3 Speed These optional and read only fields show th...

Страница 60: ...54 3 10 Load Optimized Defaults This option allows you to load the default values to your system configuration These default settings are optimal and enable all high performance features To load SETU...

Страница 61: ...NA 401 Hardware Installation Guide Award BIOS Utility 55 3 11 Set Supervisor User Password You can set either supervisor or user password or both of then The differences between are...

Страница 62: ...nter of the screen to assist you in creating a password ENTER PASSWORD Type the password with eight characters at most and press Enter The password typed will now clear any previously entered password...

Страница 63: ...nging your system configuration Additionally when a password is enabled you can also require the BIOS to request a password every time the system reboots This would prevent unauthorized use of your co...

Страница 64: ...e Award BIOS Utility 58 3 12 Save Exit Setup This allows you to determine whether or not to accept the modifications Typing Y quits the setup utility and saves all changes into the CMOS memory Typing...

Страница 65: ...ility 59 3 13 Quit Without Saving Select this option to exit the Setup utility without saving the changes you have made in this session Typing Y will quit the Setup utility without saving the modifica...

Страница 66: ...NA 401 Hardware Installation Guide Award BIOS Utility 60 This page does not contain any information...

Страница 67: ...manufacturer Dispose of used batteries according to the manufacturer s instructions z Warning for Hard Disk Drive Selection TUV approved Hard Disk Drive is preferred for TUV compliance Hard Disk drive...

Страница 68: ...to specification as nameplate Make sure the voltage of the power source when connect the equipment to the power outlet The current of load and output power of loads shall be not over the specification...