ENGINEERS MANUAL
CST MACHINES AND DRYER UNIT
Drawn up: 05/10/2018
Document number : 30008893
Page 14 of 48
Revision: C
8.
Commissioning Instructions
Rinse aid & Detergent:
The CST is not fitted with internal chemical dosing pumps, these will need to be fitted during the
installation.
A terminal block is provided on right hand side of the wash tank for connecting the electrics of the
chemical pumps.
Note:
Isolate the machine prior to the access and connection of the chemical pump terminal block.
WARNING
: Only rinse aids and detergents developed for commercial glass and
dishwashers are to be used, rinse aids must be suitable for water temperatures down to
40°C.
Terminal block configuration (Chemical pumps):
Yellow/green
Blue
orange
Purple
Brown
Earth
Neutral
Running
WT full
Live