ENGINEERS MANUAL
CST MACHINES AND DRYER UNIT
Drawn up: 05/10/2018
Document number : 30008893
Page 11 of 48
Revision: C
Electric Supply:
Electrical connection:
Electrical connections MUST be carried out by an authorized technician and in accordance with local
and national regulations.
As a minimum
Classeq
recommends the following standards are maintained:
All appliances are connected via a residual current device (R.C.D.) or earth leakage protection device.
EN60204:
Supply isolator switch has all pole separation of more than 3mm.
EN60335
:
Connect to an equi-potential conductor, connection stud located at bottom of the appliance to the rear;
this is in addition to the earthed electrical supply.
Prior to connecting the appliance, ensure voltage and supply fuse comply with rating plate
.
Electrical rating:
Note:
Electrical supply can be
either side of the appliance. The
appliance not supplied with the
electrical plugs.
If the supply cable is damaged ,
it must be replaced by a cable or
cord assembly supplied by
Classeq
or its service agents or
to the following minimum
specification.
Cable type
Temperature
rating
Length of cable
Confirm to /
standard
H07RN-F
5G10
80°C minimum
5m
IEC 60335-2-58
&
IEC 60227 types
56 & 57
Electrics
CST
Dryer unit
Volts
380
– 415V (3
Phase)
380
– 415V (3
Phase)
Amps
Hot fill
32A per phase
+12A per phase
Cold Fill
45A per phase
Max total load
Hot fill
13.74kW
+4.5kW
Cold Fill
25.74kW