ENGINEERS MANUAL
CST MACHINES AND DRYER UNIT
Drawn up: 05/10/2018
Document number : 30008893
Page 13 of 48
Revision: C
Waste outlet:
The CST is a gravity drain machine, upon installation the
waste must be configured as stated in this manual.
All installations should be fitted with a
running ‘P’ trap to
ensure hygiene.
Ø40mm (1 ½”) standpipe required, must be lower than
the baseline of the wash tank.
Drain hose must be a close / tight fit into the drain pipe
to reduce odours from the drain system.
To ensure correct drainage, the height the sites drain is from the floor / surface the machine sits
upon MUST be within the following
Waste hose must flow down from the waste outlet to the drain.
Joint between standpipe and waste hose must be water tight.
If you have any doubts about the drainage system on the machine, please contact either
Classeq
or
your dealer/agent.
Terminal block layout
Terminal block (TB1) configuration (Mains supply):
Drainage dimensions
(mm)
CST
Drain stand pipe diameter Ø40
Maximum drain pipe
height (Gravity drain)
(Depending on height
adjustment)
270 - 330mm
4mm² wires for heating
10mm² incoming mains cable
0.75mm² cable to pumps
0.5mm² neutral cable to Filter
4A
1.5mm² cable to control
harness and pumps
1.5mm² earth cable
0.75mm² cable to dryer
unit (if fitted)